❺ Troubleshoo ng
If a problem occurs, before you contact your retailer, please carry out these few simple checks
using the following tables.
If the problem con nues, contact your retailer.
: Ac ons to be performed by a qualifi ed technician only
5.1 I Appliance behaviour
The pump does not
start / the motor does
not turn.
Filtra on outside of a scheduled opera ng range (“Auto” mode). Check the ltra on
clock se ngs.
Electric power cut. Check the circuit breaker(s).
Check the connec on between the power cable and the motor terminals.
Check the user interface cable.
Incorrect confi gura on of the pump address; check the posi on of the switches (see
§ "2.4 I Connec ng the user interface (depending on the model)").
Check that the motor sha rotates freely. Ensure that there is no debris in the pre-fi lter
strainer.
If debris remains, remove the pump to access the turbine.
The pump doesn’t
prime / air can be seen in
the pre-fi lter strainer.
Check the posi on of all valves in the hydraulic circuit.
Air is stuck in the circuit, drain the hydraulic circuit (bleed screw on the fi lter).
The pool’s water level is too low, air is being sucked into the circuit; fi ll the pool.
The gasket of the pre-fi lter strainer lid is defec ve, check the condi on of the gasket
and the correct air- ghtness of the lid.
Low fl ow rate / low fi lter
pressure
Pre-fi lter strainer full of debris: clean.
Air leak in the circuit. Check all  ghtening torques.
The turbine and the pump diff user are blocked or worn, replace.
The diff user seal is worn, replace.
Reverse motor rota on (three-phase models only). Check the electrical connec on
at the pump terminals.
Low fl ow rate / high fi lter
pressure
The fi lter is clogged. Wash the fi lter (or the cartridge depending on the case).
Check the posi on of all valves in the hydraulic circuit.
Pump making a lot of
noise
Air leak or cavita on in the suc on piping. Check the posi on of the valves and adjust
where necessary.
Pump incorrectly posi oned on the ground. Check that it is res ng in a fl at posi on on
a hard, horizontal ground. Use an -vibra on studs where necessary.
A foreign body is present in the pre- lter strainer.
A foreign body is present in the pump body (in this case, the pump must be
removed).
Leak between the pump
body and the motor
The mechanical lining is damaged or defec ve, replace
The pump heats up and
switches off
The motor is overhea ng due to too li le ven la on. Check that there is enough clear
space around the motor.
There is an electrical fault. Check the power connec ons and check the mains
voltage, which must not vary.
There is nothing on the
user interface or the
external controller display
Incorrect confi gura on of the pump address; check the posi on of the switches (see
§ "2.4 I Connec ng the user interface (depending on the model)").
Check the user interface cable.
The user interface
displays 'PUMP NOT
CONNECTED"
Check the user interface cable.
Incorrect confi gura on of the pump address; check the posi on of the switches (see
§ "2.4 I Connec ng the user interface (depending on the model)").