H0335800 Rev H
Jandy
®
Heat Pumps
Model EE-Ti




WARNING
 This product must be installed by a licensed HVAC technician certied in heat
pump repair and maintenance by the jurisdiction in which the product will be installed where such
state or local requirements exists. The technician must possess and comply with all certications and
regulations regarding the purchasing, handling, transportation and reclamation of R410A refrigerant.
In the event no such state or local requirement exists, the installer or maintainer must be a
professional with sufcient experience in pool equipment installation and maintenance so that all of
the instructions in this manual can be followed exactly. Before installing this product, read and follow
all warning notices and instructions that accompany this product. Failure to follow warning notices
and instructions may result in property damage, personal injury, or death. Improper installation and/
or operation can create an electrical hazard which can cause serious injury, property damage, or
death. Improper installation and/or operation will void the warranty.

Table of Contents

Questions and Answers

  • S
    Shane JonesJul 30, 2025
    What to do if my Zodiac Jandy EE-Ti shows 'FAULT- NO FLOW'?
    • N
      Nicholas Harris IIIJul 30, 2025
      If your Zodiac Heat Pump displays a 'FAULT- NO FLOW' error, it means that the circulating pump might not be on, or the valves are not in the correct positions. First, verify that the circulating pump is indeed running and that all necessary valves are correctly positioned. Also, ensure that the filter and skimmers are clean, and the water level in the pool is adequate. Temporarily disable any fountains or waterfalls that might be bypassing the heat pump's water inlet. If the problem persists, further assistance is needed.
  • K
    Kenneth RothAug 2, 2025
    What to do if my Zodiac Jandy EE-Ti Heat Pump shows 'FAULT- HIGH REF PRESSURE'?
    • L
      Leslie ChangAug 2, 2025
      If your Zodiac Heat Pump displays 'FAULT- HIGH REF PRESSURE', it could be due to the circulating pump not running or restrictions in the water flow to the heat pump. Ensure the circulating pump is active and that there are no obstructions hindering water flow to the heat pump. Verify that all necessary valves are correctly positioned to allow proper water flow. If the heat pump hasn't been used for a while, try cycling it on and off up to three times to resolve the issue. If the problem persists, it is recommended to call for service.
  • T
    Tina HortonAug 7, 2025
    What to do if Zodiac Jandy EE-Ti shows 'FAULT- LOW REF PRESSURE'?
    • M
      Michael GarrisonAug 7, 2025
      If your Zodiac Heat Pump isn't running or is short cycling and the control board displays 'FAULT- LOW REF PRESSURE,' it could mean the fan isn't working, or air isn't coming out of the top of the heat pump. Check that the fan is running and air is being expelled from the top of the unit while it is short cycling. If the heat pump does not run at all, it is recommended to call for service.
  • A
    Amanda BentonAug 11, 2025
    How to fix a Zodiac Jandy EE-Ti that won't start and has no display?
    • S
      Sarah DavisAug 11, 2025
      If your Zodiac Heat Pump isn't starting and the control board display is blank, a possible cause is a tripped breaker or a blown fuse. Try resetting the breaker or checking the fuse. If the heat pump still fails to start after this, it is recommended to call for service. For three-phase models, this issue could also be due to reversed phases or a loss of phase, in which case you should call for service.
  • L
    Laura GrahamAug 15, 2025
    Why is my Zodiac Jandy EE-Ti Heat Pump leaking water?
    • K
      Kayla StevensAug 15, 2025
      If your Zodiac Heat Pump is leaking water, it could indicate a heat exchanger or plumbing leak. To investigate, first turn off the heat pump and then turn off the circulating pump for at least one hour to see if the water leak stops. If the water leak continues even after the heat pump has been shut off for at least one hour, it is recommended to call for service.
  • L
    Laura MartinezAug 20, 2025
    Why won't my Zodiac Heat Pump start if the display is on?
    • K
      Karla Mendoza MDAug 20, 2025
      If your Zodiac Heat Pump isn't starting but the control board display is working, it might be in a 5-minute delay countdown. Ensure the control board thermostat is set to call for heat, verifying both the thermostat setting and the temperature reading. Also, confirm that the heat pump isn't accidentally set to cooling mode.
  • J
    James PerezAug 25, 2025
    Why is my Zodiac Jandy EE-Ti Heat Pump running but not heating the water?
    • M
      Michael MedinaAug 25, 2025
      If your Zodiac Heat Pump is running but not heating, several factors could be at play. If the heat pump has just been installed or the pool water has cooled down significantly, allow the heat pump to run continuously for 24-48 hours to properly heat the water. If the heat pump has been running for a while, try increasing the circulating pump time or switch the control board to Maintain Heat function. If you are heating a spa, make sure that no air intake stand pipes are open. If the heat pump still does not heat, it is recommended to call for service.

Summary

General Information

Introduction and Product Overview

Details the manual's purpose, product overview, and contact information for Zodiac.

Consumer Safety and Tips

Covers essential safety guidelines, spa/hot tub rules, and energy saving tips.

Warranty and Compliance

Details the limited factory warranty, claim process, and applicable codes and standards.

Technical Specifications and Assistance

Provides technical specifications, dimensions, and contact for support.

Installation Instructions

General Installation Requirements

Outlines general requirements and procedures for safe and correct heat pump installation.

Location and Clearances

Specifies ideal locations, site preparation, and required clearances for installation.

Water Connections and Plumbing

Guides on plumbing layout, water connections, and flow control for the heat pump.

Electrical Connections and Wiring

Details the procedures, safety precautions, and wiring for electrical connections.

Operation

Initial Start-up and Controller Basics

Important steps before first operation and how to use the control panel.

Pool and Spa Operating Modes

Explains normal and optional maintain heat/chill modes for pool and spa.

User Setup and Customization

Allows customization of language, temperature scale, timer, and display settings.

Advanced Operation Features

Details set point lockout, remote control configuration, and pressure switch adjustment.

Maintenance and Troubleshooting

General Maintenance and Winterizing

Covers water chemistry, winterizing procedures, and general upkeep.

Inspection and Seasonal Start-Up

Guidelines for owner and professional inspections and spring start-up.

Troubleshooting and Diagnostics

Provides common symptoms, corrective actions, and diagnostic codes for issues.

Replacement Parts and Diagrams

Information on ordering parts and an exploded view of the heat pump.

Zodiac Jandy EE-Ti Specifications

General IconGeneral
TypeHeat Pump
RefrigerantR-410A
Compressor TypeScroll
Heat ExchangerTitanium
Heating Capacity140, 000 BTU/h
Voltage230V
Operating Temperature Range40°F - 104°F
ModelEE-Ti

Related product manuals