4/16
OVER PRESSURE VALVE IN THE BUOYANCY TUBE AND KEEL
Location:
• This over pressure
valve is situated in the
buoyancy tube and
keel only, one in each
chamber.
The pressure relief valve is fitted with a mesh filter cap to prevent the ingress of sand and
dirt. Do not remove the filter cap.
OVER PRESSURE VALVE IN THE HIGH PRESSURE FLOOR
(1) Cap (2) Valve
Location:
• This over pressure valve is situated in the
floor only.
1
2
CAUTION
DO NOT TRY AND INFLATE THE BOAT THROUGH THE PRESSURE
REFLIEF VALVE. SEVERE DAMAGE MAY OCCUR.
NOTE
:
THE PRESSURE RELIEF VALVES ARE SET TO OPEN WHEN THE
BUOYANCY TUBE OR KEEL PRESSURE REACHES 4 PSI
(0.275BAR). THIS PREVENTS DAMAGE TO THE CRAFT FROM
warning
•
••
• NEVER INFLATE THE BOAT OR THE HIGH PRESSURE FLOOR
WHILE THE CAPS ARE ON THE OVER PRESSURE VALVES.
•
••
• REMOVE THE CAPS DURING INFLATION AND REFIT THEM
ONCE THIS PROCEDURE IS COMPLETED.
•
••
• DURING NAVIGATION, THE CAPS MUST BE IN PLACE,
UNSCREW THEM WHEN THE BOAT IS OUT OF THE WATER.
•
••
• REGULARLY CHECK THEIR FUNCTIONING.
•
••
• TIGHTEN THE CAPS TO THE VALVES WITH JUST A ½ TURN.