E.MAINTENANCE
Forbestresultsandlongtermoperation,regularmaintenanceis
essential.
Toensurethecoolerdeliversfreshandcleanair,regularlychangethewaterwhen
dirty,andcleanboththedustfilterandthecoolingpad.
a.Removethefilterpadbyunscrewingthe4screwsontherearofthecooler.Thenliftthe
padandpulloutatthebottomtorelease.Toreplacethepad,slideupintotheslotunder
thetopofthecooler,pushinatthebottom,andallowtodropintothelowerslot.
b.Cleanthepadfromtheinner-sidetoout-sideofpadinnersideistowardsmotor).Never
useanyliquiddetergent.Neverusepressurizedwater,asitmaycausedamagetothe
pad.
c.Unscrewthedrainagelidtoletdirtywaterflowout,thencleanthewatertank.Washoff
dirtonthewatersensor,waterpumpandthefloatvalve.Rinsethoroughly.
d.Usemildsoapandsoftcleanclothwhencleaningthecoolercasing.Donotuseany
causticchemicaldetergentthatmaycausedamagetothesurfaceofthecooler.
e.Topreventbuildupofalgaeandbiologicalorganismsinthereservoir,regularlyadd
chlorine/brominetablesaspertabletmanufacturerrecommendationforevaporative
coolerreservoirs.
PORTABLEAIRCOOLER
OPERATIONINSTRUCTION
A.KEYCOMPONENTS

Questions and Answers

  • W
    william17Aug 5, 2025
    What to do if Zokop Air Conditioner display is normal but airflow is low?
    • D
      Deborah RobinsonAug 5, 2025
      If your Zokop Air Conditioner's display is normal but the airflow is too low, it could be due to several reasons. First, check if the fan is jammed and ensure nothing is preventing its free rotation. Another possible cause is a blocked cooling pad or dust filter, so clean them. If the fan is distorted, it should be replaced. A failure of the main control board could also be the cause, so consider changing it.
  • T
    Tina BaxterAug 10, 2025
    Why is the operating screen dark on my Zokop ESC-45P-4R Air Conditioner?
    • H
      hudsonstephanieAug 10, 2025
      If the operating screen on your Zokop Air Conditioner stays dark, there are several potential reasons. First, check that the unit is properly plugged in to ensure it has power. If it is, the main control board might have failed, requiring a replacement. Alternatively, the fuse may be blown, in which case you should change the fuse. Finally, the panel itself might have failed, necessitating a panel replacement.
  • S
    Stephanie RiosAug 15, 2025
    What to do if Zokop ESC-45P-4R motor does not respond to control panel?
    • H
      heatherperezAug 16, 2025
      If the motor of your Zokop Air Conditioner isn't responding to the control panel, the issue might stem from a failure in either the main control board or the panel itself. Consider changing the main control board or replacing the panel.
  • R
    Robert RobertsAug 20, 2025
    How to fix water leaking from drain valve of Zokop Air Conditioner?
    • T
      Tristan WongAug 20, 2025
      If water is leaking from the drain valve of your Zokop Air Conditioner, the drain valve might be loose; try tightening the drain valve nut. Another possibility is dirt in the valve, so try cleaning the drain valve.
  • G
    george49Aug 26, 2025
    Why is the air diffuser/swing function not working on my Zokop Air Conditioner?
    • S
      Sarah GrantAug 26, 2025
      If the air diffuser or swing function isn't working on your Zokop Air Conditioner, it could be because the synchronous motor has burnt out, requiring a replacement. Alternatively, the crankshaft might be broken, also requiring a replacement.
  • J
    Jordan GonzalezAug 30, 2025
    What to do if water drops splash out of the air diffuser of Zokop Air Conditioner?
    • R
      Ruth JacksonAug 30, 2025
      If water drops are splashing out of the air diffuser of your Zokop Air Conditioner, the water pipe may have come loose. Check the water pipe to the top of the filter pad and reattach or tighten it as necessary.

Summary

Maintenance Procedures

Filter Pad Maintenance

Instructions for removing, cleaning, and replacing the filter pad, including cleaning from the inner side.

Water Tank and Component Cleaning

Procedure for draining dirty water, cleaning the water tank, sensor, pump, and float valve.

Exterior Casing Cleaning

Guidance on cleaning the cooler casing using mild soap and a soft cloth, avoiding harsh chemicals.

Reservoir Algae Prevention

Recommendation to add chlorine/bromine tablets for preventing algae and biological organisms.

Key Components Overview

Identification of Air Cooler Parts

Labels and identification of major components of the portable air cooler.

Technical Specifications

Air Cooler Model Details

Table listing models with airflow, voltage, power, water capacity, dimensions, and net weight.

Operation Instructions and Controls

Control Panel Functions

Explanation of the keypad buttons: ON/OFF, Model, Timer, Speed, Swing, Cooling, Night.

Troubleshooting Common Malfunctions

Guide to diagnosing and solving issues like dark screen, no air flow, or motor response problems.

Overview

This document describes a Zokop Portable Air Cooler, outlining its functions, technical specifications, usage, and maintenance.

Function Description:

The Zokop Portable Air Cooler is designed to provide fresh and clean air through an evaporative cooling process. It operates by drawing in air, passing it through a wet cooling pad, and then releasing cooler, humidified air. The device features various modes and controls to customize the user experience, including different fan speeds, cooling functions, and an auto-swing feature for wider air distribution. It is intended for indoor use to improve air quality and comfort.

Important Technical Specifications:

The manual provides specifications for three models: ESC-45P-4R, ESC-50P-4R, and ESC-60P-5RN.

  • ESC-45P-4R:
    • Airflow: 4500 cmh
    • Voltage: 110V/60Hz
    • Power: 120W
    • Water Capacity: 40L
    • Dimensions (cm): 49 x 36.5 x 97
    • Net Weight: 12.5kg
  • ESC-50P-4R:
    • Airflow: 5000 cmh
    • Voltage: 110V/60Hz
    • Power: 150W
    • Water Capacity: 50L
    • Dimensions (cm): 56 x 37 x 110
    • Net Weight: 15kg
  • ESC-60P-5RN:
    • Airflow: 7000 cmh
    • Voltage: 110V/60Hz
    • Power: 200W
    • Water Capacity: 70L
    • Dimensions (cm): 66 x 46 x 117
    • Net Weight: 20kg

All models operate on a 110V/60Hz power supply, indicating they are designed for regions with this electrical standard. The varying airflow, power consumption, water capacities, and dimensions allow users to choose a model suitable for different room sizes and cooling needs.

Usage Features:

The cooler is equipped with a control panel and various operational modes:

  • ON/OFF: Starts or stops the cooler.
  • Model: Allows selection between Normal, Natural, or Sleep modes, catering to different comfort preferences throughout the day or night.
  • Timer: Enables setting a working time from 1 hour to 12 hours, providing convenience and energy saving.
  • Speed: Offers low, medium, or high fan speed settings to adjust the intensity of air circulation.
  • Swing: Activates the auto-swing function for the vent, moving it left and right to distribute air more broadly across a room.
  • Cooling: Engages the pump to start the evaporative cooling process, activating the cooling function.
  • Night: Turns on/off the light of the screen, useful for nighttime operation to avoid disturbance.

Key components visible on the device include a control panel, swing vents, water tank, and wheels for portability. Other components mentioned are tempered glass, a PP shell, power cord, dust cover, cooling pad, and a water level display.

Maintenance Features:

Regular maintenance is crucial for optimal performance and longevity of the air cooler.

  • Water Change: Regularly change the water when it becomes dirty to ensure fresh and clean air delivery.
  • Filter Pad and Cooling Pad Cleaning: Both the dust filter and the cooling pad require regular cleaning.
    • To remove the filter pad, unscrew the four screws on the rear of the cooler, lift the pad, and pull it out from the bottom. To replace, slide it up into the slot under the top of the cooler, push it in at the bottom, and let it drop into the lower slot.
    • Clean the pad from the inner side (towards the motor) to the outer side. Do not use any liquid detergent or pressurized water, as it can damage the pad.
  • Water Tank Cleaning: Unscrew the drainage lid to empty dirty water, then clean the water tank. Wash off dirt from the water sensor, water pump, and float valve, then rinse thoroughly.
  • Casing Cleaning: Use mild soap and a soft, clean cloth to clean the cooler casing. Avoid caustic chemical detergents, which can damage the surface.
  • Algae and Biological Organism Prevention: To prevent the buildup of algae and other biological organisms in the reservoir, regularly add chlorine/bromine tablets according to the tablet manufacturer's recommendations for evaporative cooler reservoirs.

The troubleshooting section also provides guidance on common issues and their solutions, such as checking the unit is plugged in for a dark operating screen, cleaning the cooling pad for low airflow, tightening the drain valve for water leaks, and replacing specific components like the main control board, fuse, fan, synchronous motor, or crankshaft if they malfunction. For complex issues, users are advised to contact their distributor for service.

Zokop ESC-45P-4R Specifications

General IconGeneral
BrandZokop
ModelESC-45P-4R
CategoryAir Conditioner
LanguageEnglish