Instruction for use of the forklift with the triple pivot battery
42
5.4 Hydraulic system
No or less oil in
system
1. The pipeline or connector has air leakage
Inspect and repair
2. Lower level in the oil tank
Check the refueling
3. Too much impurity in oil and the oil filter clogged
Change oil
4. Excessive wear of gear pump
Replace
5. The seal ring in the gear pump is damaged.
Check and replace
Weak lifting force
or unable to lift
1. Excessive wear of gear pump
Replace
2. Insufficient system pressure
Adjust the safety valve pressure
3. The multi-way valve and valve rod are overworn
Replace or renew valve rod
4. The lifting cylinder leaks inside
Replace the seal ring
5. The safety valve doesn’t reset.
Inspect and repair
5.5. Electric System
No voltage when
the key switch is
turned on.
1. The key switch is in poor contact.
Replace
2. Disconnection
Reconnection
3. The connector is in poor contact
Replace or repair
4.The connector of battery is loose
Tighten the connecting bolt.
When the
acceleration pedal
is depressed, the
forklift doesn’t
move.
1. Disconnection
Reconnection
2. The connector is in poor contact
Replace or repair
3. The direction switch is in poor contact.
Replace or repair
4. The speeder has a fault
Check or replace
The lifting motor
doesn’t run
1. The speeder has a fault
Replace the contactor
2. The lifting switch doesn’t work properly.
Check or replace
3. Disconnection
Reconnection
4. The connector is in poor contact.
Replace or repair
The lifting motor
permanently rotates
1. The lifting switch doesn’t work properly.
Repair
The lighting lamp
doesn’t work
properly
1. The fuse is burn out
Replace
2. The connector is in poor contact.
Replace or repair
3. The bulb is damaged
Replace
The horn doesn’t
sound
1. The connector is in poor contact.
Replace or repair
2. The horn switch is in poor contact.
Repair
3. Horn ring
Replace
The horn keeps
buzzing
1. The horn switch is in constant connection.
Repair