ZE205E/ZE230E OPERATION MANUAL
Basic operation technique of
the excavator
c) Fuel level gauge: display range is from 0 to 100%and the red segment is 0 to 10%.
3 Basic operating instructions
3.3.1 The basic checking items
1. You cannot completely rely on the monitor to determine the machine’s status. While doing
daily checks before startup, you should get off from the machine and conduct direct checks for all
items instead of simply relying on the monitor.
Before starting the engine, you must check two
basic items: coolant low-level alarm and maintenance
prompts. If there are any abnormalities, corresponding
instruments will go on and the buzzer will sound.
a) Coolant low-level alarm
This indicator warns the operator that the coolant level in this radiator has dropped. If coolant level in
this radiator is too low, the light turns red. Then you should check the coolant levels in this radiator and
auxiliary tank and add water, as shown in Figure 3-62.
b) Maintenance prompts indicator
Maintenance prompt indicator is a warning light to remind the operator that the set time since the last
maintenance is up, as shown in Figure 3-63.
This warning stops and returns to normal operation
status after 5 seconds. If the maintenance is completed,
you can press the "OK" button on the screen, indicating
that the maintenance is completed.
If you need to change the setting of maintenance
period, please contact Zoomlion or Zoomlion dealer.
c) Charge indicator
Battery voltage alarm warns the operating personnel
that there is charging abnormalities while the engine is
running. If the battery did not properly charged when the
engine is running, the corresponding alarm icon will go
on, along with text prompts, as shown in Figure 3-64
d) Fuel level too low alarm
When this alarm light is on, the operator is warned that the fuel level is too low, the fuel left can only
support the machines to work for 1 to 2 hours and he should add fuel as soon as possible, as shown in
Figure 3-63 Maintenance prompt
indicator
Warning
Figure 3-62 Coolant low-level alarm
Figure 3-64 Charge indicators