Chapter2RoutineMaintenance
IndicatorStatusDescription
YellowLEDashesslowly
everytwoseconds.
Thesoftwareversionofthecarddoesnotmatch
thatoftheswitchingandcontrolcard.Auto-update
isnotconguredonthecard.
GreenLEDisOFF.The10GEopticalinterfaceisnotconnectedorthe
linkisnotestablished.
GreenLEDisON.The10GEopticalinterfaceisconnected(LINK).
ACTi(i=14)
GreenLEDashes.The10GEopticalinterfaceissendingand
receivingthedata(ACTIVE).
10GE/40GEEthernetUplinkCard
Table2-10describestheindicatorsofthe10GE/40GEEthernetuplinkcard.
Table2-10IndicatorDescriptionof10GE/40GEEthernetUplinkCard
IndicatorStatusDescription
OFFlThecardisnotpoweredON.
lThecarddoesnotmatch.
lCPUisnotstarted.
GreenLEDisON.Thecardself-checkingcompletesbutfailsto
receivedatafromtheswitchingandcontrolcard
orNM.
GreenLEDashes
irregularly.
Thecardisdownloadingdatafromtheswitching
andcontrolcardorthenetworkmanagement
server.
GreenLEDashesslowly
everytwoseconds.
Thecardrunsproperly.
RedLEDisON.Cardhardwarefailure
RedLEDashesslowly
everytwoseconds.
Thecardisinstalledinthewrongslot.
RUN
YellowLEDashesslowly
everytwoseconds.
Thesoftwareversionofthecarddoesnotmatch
thatoftheswitchingandcontrolcard.Auto-update
isnotconguredonthecard.
GreenLEDisOFF.Theopticalinterfaceisnotconnectedorthelink
isnotestablished.
GreenLEDisON.Theopticalinterfaceisconnected(LINK).
ACTi(i=14)
GreenLEDashes.Theopticalinterfaceissendingandreceivingthe
data(ACTIVE).
10GE/GEEthernetUplinkCard
Table2-11describestheindicatorsofthe10GE/GEEthernetuplinkcards.