ZXA10C300MaintenanceManual
Table2-11IndicatorDescriptionof10GE/GEEthernetUplinkCard
IndicatorStatusDescription
OFFlThecardisnotpoweredON.
lThecarddoesnotmatch.
lCPUisnotstarted.
GreenLEDisON.Thecardself-checkingcompletesbutfailsto
receivedatafromtheswitchingandcontrolcard
orNM.
GreenLEDashes
irregularly.
Thecardisdownloadingdatafromtheswitching
andcontrolcardorthenetworkmanagement
server.
GreenLEDashesslowly
everytwoseconds.
Thecardrunsproperly.
RedLEDisON.Cardhardwarefailure
RedLEDashesslowly
everytwoseconds.
Thecardisinstalledinthewrongslot.
RUN
YellowLEDashesslowly
everytwoseconds.
Thesoftwareversionofthecarddoesnotmatch
thatoftheswitchingandcontrolcard.Auto-update
isnotconguredonthecard.
GreenLEDisOFF.Theopticalinterfaceisnotconnected.
GreenLEDisON.Theopticalinterfaceisconnected(LINK).
XG1/XG2/GE1/
GE2
GreenLEDashes.Theopticalinterfaceissendingandreceivingthe
data(ACTIVE).
GEEthernetUplinkCard
Table2-12describestheindicatorsoftheGEEthernetuplinkcards.
Table2-12IndicatorDescriptionofGEEthernetUplinkCard
IndicatorStatusDescription
OFFlThecardisnotpoweredON.
lThecarddoesnotmatch.
lCPUisnotstarted.
GreenLEDisON.Thecardself-checkingcompletesbutfailsto
receivedatafromtheswitchingandcontrolcard
orNM.
GreenLEDashes
irregularly.
Thecardisdownloadingdatafromthemaincontrol
andswitchingcardorthenetworkmanagement
server.
RUN
2-10