ZXR10AlarmHandlingManual
Appendix
Specication
N.A.
POEAlarm
30720
MessageNo.
30720
DefaultSecurity
Level
6
AlarmRecovery
None
AlarmType
SoftProtocolAlarm
NMLevel
5
Cause
PSEdisablesPOEfunctionbecauseofover-temperatureonthe
switch;PSErecoversPOEfunctionbecauseoftemperaturerecov-
ers;PSEtotalpowerofthepowersupplyexceedspowerthreshold
orrecoversintherangeofpowerthreshold.
Inuence
CancelPOEfunctionduetohightemperature;PSEismadenotto
supplypowerbecausethetotalpowerofthepowersupplyexceeds
powerthreshold.
Recommended
Operations
Checkifthetemperatureofenvironmentwhereswitchisinistoo
high.
AlarmDescription
Prototype
DisablePOEfunctionbecausethatthewholePSEisover-temper-
atureontheswitch.
Disablepoefunctionofthepse%dbecauseofover-temperature
ontheswitch
Example:
09:40:1011/13/2008UTCalarm30721occurred%POE%Dis-
ablepoefunctionofthepse1becauseofover-temperatureonthe
switchsentbyMEC1
PSEtotalpowerofthepowersupplyexceedspowerthresholdor
recoversintherangeofpowerthreshold.
Theusagepower(%dw)isbelowthePSEthreshold(%dw)onpse
%d
Therst%d:PSEtotalpowerofthepowersupply
Thesecond%d:PSEpowerthreshold.
Thethird%d:PSEdevicenumber .
Theusagepower(%dw)isabovethePSEthreshold(%dw)onpse
%d
Therst%d:PSEtotalpowerofthepowersupply
Thesecond%d:PSEpowerthreshold.
Thethird%d:PSEdevicenumber .
Example:
132CondentialandProprietaryInformationofZTECORPORATION