EasyManua.ls Logo

Zte ZXR10 - Page 164

Zte ZXR10
307 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ZXR10AlarmHandlingManual
Appendix
Specication
N.A.
POEAlarm
30720
MessageNo.
30720
DefaultSecurity
Level
6
AlarmRecovery
None
AlarmType
SoftProtocolAlarm
NMLevel
5
Cause
PSEdisablesPOEfunctionbecauseofover-temperatureonthe
switch;PSErecoversPOEfunctionbecauseoftemperaturerecov-
ers;PSEtotalpowerofthepowersupplyexceedspowerthreshold
orrecoversintherangeofpowerthreshold.
Inuence
CancelPOEfunctionduetohightemperature;PSEismadenotto
supplypowerbecausethetotalpowerofthepowersupplyexceeds
powerthreshold.
Recommended
Operations
Checkifthetemperatureofenvironmentwhereswitchisinistoo
high.
AlarmDescription
Prototype
DisablePOEfunctionbecausethatthewholePSEisover-temper-
atureontheswitch.
Disablepoefunctionofthepse%dbecauseofover-temperature
ontheswitch
Example:
09:40:1011/13/2008UTCalarm30721occurred%POE%Dis-
ablepoefunctionofthepse1becauseofover-temperatureonthe
switchsentbyMEC1
PSEtotalpowerofthepowersupplyexceedspowerthresholdor
recoversintherangeofpowerthreshold.
Theusagepower(%dw)isbelowthePSEthreshold(%dw)onpse
%d
Therst%d:PSEtotalpowerofthepowersupply
Thesecond%d:PSEpowerthreshold.
Thethird%d:PSEdevicenumber .
Theusagepower(%dw)isabovethePSEthreshold(%dw)onpse
%d
Therst%d:PSEtotalpowerofthepowersupply
Thesecond%d:PSEpowerthreshold.
Thethird%d:PSEdevicenumber .
Example:
132CondentialandProprietaryInformationofZTECORPORATION