Chapter2AlarmMessage
19:38:2306/19/2006UTCalarm30720occurred%POE%Theus-
agepower(0w)isbelowthePSEthreshold(30w)onpse1sent
byMCP
AlarmDescription
1.PSEdisablesPOEfunctionbecauseofover-temperatureonthe
switch.
2.PSEtotalpowerofthepowersupplyrecoversintherangeof
powerthreshold.
SupportedDevices
ZXR103928A-PSZXR105928-PS
30721
MessageNo.
30721
DefaultSecurity
Level
6
AlarmRecovery
None
AlarmType
SoftProtocolAlarm
NMLevel
5
Cause
noresponsefromport,noresponsefromchip,noresponsefrom
rmware,overload.DeviceabnormalitycausesthatPOEport
powersupplyiscancelled.
Inuence
POEfunctionontheportisinvalidandpowersupplyisdisabled.
Recommended
Operations
Checkdeviceaccordingtotheprompt.
AlarmDescription
Prototype
POEontheportisdisabled.
PoEdisable(fornoresponsefromport)
Example:
09:40:1011/13/2008UTCalarm30720occurred%POE%PoEdis-
able(fornoresponsefromport)ongei_2/1/24sentbyMEC1
Theportpowersupplystatusischanging.
ThePSEpowerdetectionstatusissearching
ThePSEpowerdetectionstatusisdeliveringPower
Example2:
17:52:0906/19/2006UTCalarm30721occurred%POE%ThePSE
powerdetectionstatusisdeliveringPowerongei_1/10sentbyMCP
AlarmDescription
1.Powersupplyfunctionongei_2/1/24iscancelledbecauseof
noresponsefromport.
2.Thepowersupplystatusongei_1/10becomesbeinginpower
supply.
CondentialandProprietaryInformationofZTECORPORATION133