ZXR10AlarmHandlingManual
AlarmPrototype
Description
AlarmOccurred
%sPanel%dCurrentlocaltemperatureis%d℃/%dF ,exceedsthe
secondhighthreshold(%d℃/%dF)
AlarmCleared
%sPanel%dCurrentlocaltemperatureis%d℃/%dF ,underthe
secondhighthreshold(%d℃/%dF)
Therst%sistheboardtype,therst%disthepanelnumber
oftheboard,thesecond%disthecentigradetemperatureofthe
board,thethird%distheFahrenheittemperatureofboard,the
fourth%disthecentigradetemperatureofthesetthresholdand
thefth%distheFahrenheittemperatureofthesetthreshold.
AlarmOccurred
%sCurrentlocaltemperatureis%d℃/%dF ,exceedsthesecond
highthreshold(%d℃/%dF)
AlarmCleared
%sCurrentlocaltemperatureis%d℃/%dF ,underthesecondhigh
threshold(%d℃/%dF)
Therst%sistheboardtypeandisxedtoBICboard.Thereis
nopanelnumberonBICboard,sothedisplayformatisdifferent
fromotherboard:therst%disthecentigradetemperatureof
theboard,thesecond%distheFahrenheittemperatureofboard,
thethird%disthecentigradetemperatureofthesetthresholdand
thefourth%distheFahrenheittemperatureofthesetthreshold.
Analarm65level5occurredat01:58:4001/28/2001UTCsent
byUPC(MPU)2%ENVIRONMENT%SFCPanel1Currentlocaltem-
peratureis33℃/91F ,exceedsthesecondhighthreshold(32℃/89F)
Analarm65level5clearedat01:58:5001/28/2001UTCsentby
UPC(MPU)2%ENVIRONMENT%SFCPanel1Currentlocaltem-
peratureis33℃/91F ,underthesecondhighthreshold(30℃/86F)
AlarmDescription
Boardtemperatureishigherthanthesetsecond-hightemperature
threshold.
SupportedDevices
T128/T64,T600/T1200
Appendix
Specication
N.A.
66
MessageNo.
66
DefaultSeverity
Level
5
AlarmRecovery
Available
AlarmType
EnvironmentalAlarm
NMLevel
4
Cause
TheCPUutilizationexceedsthesetmemoryutilizationthreshold.
Thecommandusedtosetthresholdformemoryutilizationis(un-
derenvironmentalcongurationmode):memory-threshold.
Recommended
Operations
UsethecommandshowprocesstoviewtheCPUutilizationand
analyzsewhetheritisnormalornot.
12CondentialandProprietaryInformationofZTECORPORATION