Chapter2AlarmMessage
AlarmPrototype
Description
AlarmOccurred
%s(M)panel%dexceedsmemoryrateis:%3.3f%%underthe
alarmthresholdis%d%%
%s(S)panel%dexceedsmemoryrateis:%3.3f%%underthe
alarmthresholdis%d%%
AlarmCleared
%s(M)panel%dcurrentmemoryrateis:%3.3f%%underthe
alarmthresholdis%d%%
%s(S)panel%dcurrentmemoryrateis:%3.3f%%underthe
alarmthresholdis%d%%
Therst%sisCPUtype,therst%disCPUSlotNo,therst%fis
thecurrentCPUutilizationandthesecond%disthesetmemory
utilizationthreshold.
Analarm66level5occurredat01:47:5001/28/2001UTCsent
byUPC(MPU)2%ENVIRONMENT%SP(M)panel1currentmemory
rateis:40.562%exceedsthealarmthresholdis2%
Analarm66level5clearedat01:48:2001/28/2001UTCsentby
UPC(MPU)2%ENVIRONMENT%RP(M)panel2currentmemory
rateis:40.084%underthealarmthresholdis60%
AlarmDescription
CPUutilizationexceedsthesetmemoryutilizationthreshold.Itis
60%bydefault.
SupportedDevices
T128/T64,T600/T1200
Appendix
Specication
N.A.
67
MessageNo.
67
DefaultSeverity
Level
5
AlarmRecovery
Available
AlarmType
EnvironmentalAlarm
NMLevel
4
Cause
Theremotetemperatureislowerthanthesetremotelowerthresh-
oldoftheboard.
Thecommandusedtosetthresholdforequipmenttemperature:
temper-thresholdUPCmasterlocallowthreshold-20rst-high-
threshold55second-highthreshold90.
RelatedAlarms
68,69
Recommended
Operations
Increasetheenvironmenttemperatureoftheequipmentifneces-
sary.
AlarmPrototype
Description
AlarmOccurred
%sPanel%dCurrentremotetemperatureis%d℃/%dF ,underthe
lowthreshold(%d℃/%dF)
AlarmCleared
%sPanel%dCurrentremotetemperatureis%d℃/%dF ,exceeds
thelowthreshold(%d℃/%dF)