ZXR10AlarmHandlingManual
Recommended
Operations
Decreasetheboardtemperatureifnecessary.Decreasetheenvi-
ronmenttemperatureoftheequipmentbythefanheatdissipation.
Ifthetemperatureistoohigh,stopusingtheboard.
AlarmPrototype
Description
AlarmOccurred
%sPanel%dCurrentremotetemperatureis%d℃/%dF ,exceeds
thesecondhighthreshold(%d℃/%dF)
AlarmCleared
%sPanel%dCurrentremotetemperatureis%d℃/%dF ,underthe
secondhighthreshold(%d℃/%dF)
Therst%sistheboardtype,therst%disthepanelnumber
oftheboard,thesecond%disthecentigradetemperatureofthe
board,thethird%distheFahrenheittemperatureofboard,the
fourth%disthecentigradetemperatureofthesetthresholdand
thefth%distheFahrenheittemperatureofthesetthreshold.
AlarmOccurred
%sCurrentremotetemperatureis%d℃/%dF ,exceedsthesecond
highthreshold(%d℃/%dF)
AlarmCleared
%sCurrentremotetemperatureis%d℃/%dF ,underthesecond
highthreshold(%d℃/%dF)
Therst%sistheboardtypeandisxedtoBICboard.Thereis
nopanelnumberonBICboard,sothedisplayformatisdifferent
fromotherboard:therst%disthecentigradetemperatureof
theboard,thesecond%distheFahrenheittemperatureofboard,
thethird%disthecentigradetemperatureofthesetthresholdand
thefourth%distheFahrenheittemperatureofthesetthreshold.
Analarm69level5occurredat02:02:4001/28/2001UTC
sentbyUPC(MPU)2%ENVIRONMENT%SFCPanel1Current
remotetemperatureis51℃/123F ,exceedsthesecondhighthresh-
old(50℃/122F)
Analarm69level5clearedat02:02:5001/28/2001UTC
sentbyUPC(MPU)2%ENVIRONMENT%SFCPanel1Current
remotetemperatureis51℃/123F ,underthesecondhighthresh-
old(100℃/212F)
AlarmDescription
Theremotetemperatureishigherthanthesetremotesecond-high
thresholdoftheboard.
SupportedDevices
T128/T64,T600/T1200
Appendix
Specication
N.A.
73
MessageNo.
73
DefaultSeverity
Level
5
AlarmRecovery
Available
AlarmType
EnvironmentalAlarm
NMLevel
4
16CondentialandProprietaryInformationofZTECORPORATION