Chapter2AlarmMessage
Cause
Theracktemperatureishigherthanthesetsinglehighthreshold.
Inuence
Thisleadstotheabnormalworkingoftheswitch.
Recommended
Operations
Lowertheenvironmenttemperatureoftherackbyusingfanheat
dissipation.
AlarmPrototype
Description
Alarmoccured
Currenttemperatureis%dC/%dF ,exceedsthethresh-
old(%dC/%dF)
Alarmcleared
Currenttemperatureis%dC/%dF ,underthethreshold(%dC/%dF)
Therst%distheenvironmentCentigradedegree;thesecond
%distheFahrenheitdegree;thethird%distheenvironment
Centigradedegreeofthesetthreshold;thefourth%distheenvi-
ronmentFahrenheitdegreeofthesetthreshold.
Alarmoccured
16:20:3106/26/2008UTCalarm73occurred%ENVIRON-
MENT%Currenttemperatureis90C/194F ,exceedsthethresh-
old(80C/176F)
Alarmcleared
16:22:1106/26/2008UTCalarm73cleared%ENVIRONMENT%
Currenttemperatureis80C/176F ,underthethreshold(90C/194F)
AlarmDescription
Theracktemperatureishigherthanthesetsinglehighthreshold.
SupportedDevices
ZXR103900/3200,5900/5200andG-seriesswitch.
Appendix
Specication
N.A.
74
MessageNo.
74
DefaultSeverity
Level
5
AlarmRecovery
Available
AlarmType
EnvironmentalAlarm
NMLevel
3
Cause
Thepowerworksabnormally.
Inuence
Thisleadstotheabnormalworkingoftheswitch.
Recommended
Operations
Checkwhetherthepowerinputisnormalandwhethertherack
outputisnormal;whetherthepowermoduleispluggedcorrectly;
whethertheconnectionisOK.
AlarmPrototype
Description
Alarmoccured
Power%ddonotwork!
Alarmcleared
Power%drestart!
%d:thepowerserialnumber .Multiplepowerstatescanbedis-
playedsimultaneously.
UAS10800E:
CondentialandProprietaryInformationofZTECORPORATION17