EasyManua.ls Logo

Zte ZXR10 - Page 49

Zte ZXR10
307 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter2AlarmMessage
Cause
Theracktemperatureishigherthanthesetsinglehighthreshold.
Inuence
Thisleadstotheabnormalworkingoftheswitch.
Recommended
Operations
Lowertheenvironmenttemperatureoftherackbyusingfanheat
dissipation.
AlarmPrototype
Description
Alarmoccured
Currenttemperatureis%dC/%dF ,exceedsthethresh-
old(%dC/%dF)
Alarmcleared
Currenttemperatureis%dC/%dF ,underthethreshold(%dC/%dF)
Therst%distheenvironmentCentigradedegree;thesecond
%distheFahrenheitdegree;thethird%distheenvironment
Centigradedegreeofthesetthreshold;thefourth%distheenvi-
ronmentFahrenheitdegreeofthesetthreshold.
Alarmoccured
16:20:3106/26/2008UTCalarm73occurred%ENVIRON-
MENT%Currenttemperatureis90C/194F ,exceedsthethresh-
old(80C/176F)
Alarmcleared
16:22:1106/26/2008UTCalarm73cleared%ENVIRONMENT%
Currenttemperatureis80C/176F ,underthethreshold(90C/194F)
AlarmDescription
Theracktemperatureishigherthanthesetsinglehighthreshold.
SupportedDevices
ZXR103900/3200,5900/5200andG-seriesswitch.
Appendix
Specication
N.A.
74
MessageNo.
74
DefaultSeverity
Level
5
AlarmRecovery
Available
AlarmType
EnvironmentalAlarm
NMLevel
3
Cause
Thepowerworksabnormally.
Inuence
Thisleadstotheabnormalworkingoftheswitch.
Recommended
Operations
Checkwhetherthepowerinputisnormalandwhethertherack
outputisnormal;whetherthepowermoduleispluggedcorrectly;
whethertheconnectionisOK.
AlarmPrototype
Description
Alarmoccured
Power%ddonotwork!
Alarmcleared
Power%drestart!
%d:thepowerserialnumber .Multiplepowerstatescanbedis-
playedsimultaneously.
UAS10800E:
CondentialandProprietaryInformationofZTECORPORATION17

Other manuals for Zte ZXR10