ZXR10AlarmHandlingManual
CurrentPowerModule%disremoved
%d:powermodulenumber
Alarmcleared
CurrentPowerworknormal
%d:thepowerserialnumber .Multiplepowerstatescanbedis-
playedsimultaneously.
Example:
Alarmoccured
15:20:3106/26/2008UTCalarm74occurred%ENVIRONMENT%
Power1donotwork!
Alarmcleared
15:21:306/26/2008UTCalarm74occurred%ENVIRONMENT%
Power1restart!
AlarmDescription
Thepowerworksabnormally.
SupportedDevices
ZXR103900/3200,5900/5200,G-seriesswitchandZX-
UAS-UAS10600,UAS10800E.
Appendix
Specication
N.A.
75
MessageNo.
75
DefaultSeverity
Level
5
AlarmRecovery
Available
AlarmType
EnvironmentalAlarm
NMLevel
4
Cause
Thefanworksabnormally.
Inuence
Thisleadstotheabnormalworkingoftheswitch.
Recommended
Operations
Checkwhetherthepowerinputandoutputofthefanisnormal;
whetherthefansarepluggedcorrectly;whetherthefuseisOK.
AlarmPrototype
Description
Alarmoccured
Fan%ddonotwork!
Alarmcleared:
Fan%drestart!
%d:thepowerserialnumber .Multiplepowerstatescanbedis-
playedsimultaneously.
UAS10800E:
CurrentT runk%sFanfailtowork
%s:T oporBottom
Alarmcleared
CurrentCabinet/TrunkFanworknormal
%s:T oporBottom
18CondentialandProprietaryInformationofZTECORPORATION