Chapter2AlarmMessage
Example:
Alarmoccured
15:10:1106/26/2008UTCalarm75occurred%ENVIRONMENT%
Fan1donotwork!
Alarmcleared
15:13:1306/26/2008UTCalarm75occurred%ENVIRONMENT%
Fan1restart!
AlarmDescription
Thefanworksabnormally.
SupportedDevices
ZXR103900/3200,5900/5200,G-seriesswitchandZX-
UAS-UAS10600,UAS10800E.
Appendix
Specication
N.A.
79
MessageNo.
79
DefaultSeverity
Level
6
AlarmRecovery
Available
AlarmType
EquipmentAlarm
NMLevel
1
Cause
Powermalfunction.
Inuence
Thisleadstotheabnormalworkingoftheboard.
RelatedAlarms
76,77
Recommended
Operations
Waitforourcustomerservicepersonneltodealwiththepower
modelmalfunction.
AlarmPrototype
Description
Alarmoccurred
Powererrorreason%s
Alarmcleared:
Powerrecover:%s
%s:thecauseforthismalfunction
Thecontentof%sis:
�Newrackalarm(onlybeappliedfornewrack)
i.CurrentPowerModule1failtowork
15:02:3808/14/2008UTCalarm79occurredPowerer-
ror ,reason:CurrentPowerModule1failtoworksentby
UPC(MPU)
ii.CurrentPowerModule2failtowork
15:04:0808/14/2008UTCalarm79occurredPowerer-
ror ,reason:CurrentPowerModule2failtoworksentby
UPC(MPU)1
iii.CurrentPowerModule3failtowork
CondentialandProprietaryInformationofZTECORPORATION19