ZXR10AlarmHandlingManual
15:06:0808/14/2008UTCalarm79occurredPowerer-
ror ,reason:CurrentPowerModule3failtoworksentby
UPC(MPU)1
�Oldrackalarm:
i.CurrentPowerCommutateModule1failtowork
15:07:3808/14/2008UTCalarm79occurredPowererror ,
reason:CurrentPowerCommutateModule1failtowork
sentbyUPC(MPU)1
ii.CurrentPowerCommutateModule2failtowork
15:46:0208/14/2008UTCalarm79occurredPowererror ,
reason:CurrentPowerCommutateModule2failtowork
sentbyUPC(MPU)115:46:0208/14/2008UTCalarm79
occurredPowererror ,reason:CurrentPowerCommutate
Module2failtoworksentbyUPC(MPU)1
iii.CurrentPowerCommutateModule3failtowork
15:47:3208/14/2008UTCalarm79occurredPowererror ,
reason:CurrentPowerCommutateModule3failtowork
sentbyUPC(MPU)1
�Generalalarm:
i.Thepowerdatalineisn'tpluggedintothebicboard
14:32:3808/14/2008UTCalarm79occurredPowererror ,
reason:Thepowerdatalineisn'tpluggedintothebicboard
sentbyUPC(MPU)1
ii.CurrentPowerworknormal
15:05:0808/14/2008UTCalarm79clearedPowerrecover:
CurrentPowerworknormalsentbyUPC(MPU)1
AlarmDescription
Powermalfunction.
SupportedDevices
ZXR10T64E,T128,T600,T1200
Appendix
Specication
ZXR10T64,T128adoptsoldrack;ZXR10T600,T1200adoptsnew
rack.
80
MessageNo.
80
DefaultSeverity
Level
6
AlarmRecovery
Available
AlarmType
EquipmentAlarm
NMLevel
2
Cause
Fanmalfunction.
Inuence
Thismaycauseheatdissipationmalfunctionontherackandthe
temperatureincrementoneachsingleboard.
Recommended
Operations
Waitforourcustomerservicepersonneltodealwiththefanmal-
function.
20CondentialandProprietaryInformationofZTECORPORATION