Chapter2AlarmMessage
Toavoidcontinuousswitchoverofmaster/slaveSFC,weseta
limittotheswitchover .Whenthresholdisexceeded,master/slave
switchoverofSFCwillstop.
Inuence
Thelinecardwithmalfunctionleadstotheactive/standby
switchover .
RelatedAlarms
294,alarmgeneratedbylinecardoutofsynchronism.
Recommended
Operations
No.
AlarmPrototype
Description
Pannel%dSFCisexchangedtobeslavebecauseswitch-module
isunsynchronous.
%d:SFCslotnumber
11:15:5703/21/2008UTCalarm302occurredPannel1SFCis
exchangedtobeslavebecauseswitch-moduleisunsynchronous.
sentbyUPC(MPU)1
AlarmDescription
SFCsynchronizationfails.Master/slaveswitchoverofSFCwilloc-
curandalarmissentout
SupportedDevices
T64E/T128
Appendix
Specication
N.A.
303
MessageNo.
303
DefaultSeverity
Level
6
AlarmRecovery
Unavailable
AlarmType
EquipmentAlarm
NMLevel
5
Cause
Itfailstoread/writecardmemoryduetotheproblemofhardware.
Inuence
Thesingleboardcannotworknormally.Thethreadapplicationon
thesingleboardmaysuspendduetotheabnormalmemory
RelatedAlarms
No.
Recommended
Operations
Waitforengineerfromcustomerservicedepartmenttodealwith
thefaultlinecard
AlarmPrototype
Description
Pannel:%dNPC%sdataeyeabnormal.
%dlinecardslotnumber
%sMaster/slave,Master/slavelinecard
13:31:3003/25/2008UTCalarm303occurredPannel:7NPCmas-
terdataeyeabnormal.sentbyUPC(MPU)1
AlarmDescription
Thethreadapplicationonthesingleboardmaysuspenddueto
theabnormalmemoryread-write.
SupportedDevices
T64E/T128,T1200
CondentialandProprietaryInformationofZTECORPORATION25