ZXR10AlarmHandlingManual
Appendix
Specication
N.A
310
MessageNo.
310
DefaultSeverity
Level
6
AlarmRecovery
Unavailable
AlarmType
EquipmentAlarm
NMLevel
5
Cause
Thehardwareisinstable.Failstowritetotheregisterininterface
boardinitializationortheplatformcommandconguration.
Inuence
Theinterfaceboardorthelinecardcannotworknormally.The
platformcommandcongurationfails.
RelatedAlarms
No.
Recommended
Operations
Plugtheinterfaceboardorthelinecardagain.Ifthemalfunction
stillexists,thencontactZTEcustomerservicepersonneltocheck
whethertheinterfaceboardorthelinecardisabnormal.
AlarmPrototype
Description
writeregisterfailed:baseaddr=0x%08x,offset=0x%4x
%08x:thebaseaddress
%04x:theoffsetaddress
Example:
14:17:5605/20/2008UTCalarm303occurred%Board%write
registerfailed:baseaddr=0xC6002000,offset=0x0006sentby
NPC2
AlarmDescription
Alarmappearswhenthelinecardfailstomodifytheregister .
Alarmmayalsoappearwhenfailingtowritetotheregisterin
interfaceboardinitializationortheplatformcommandcongura-
tion.Itisusedtodiagnosethehardwareabnormity.
SupportedDevices
T64E/T128,T600/T1200
Appendix
Specication
N.A
311
MessageNo.
311
DefaultSeverity
Level
5
AlarmRecovery
Unavailable
AlarmType
EquipmentAlarm
NMLevel
5
Cause
Theboardlinkforwardingisabnormal.
Inuence
Thecorrespondinghardwarereboots.
RelatedAlarms
No.