EasyManua.ls Logo

Zummo Z10 - Routine Maintenance Procedures; Troubleshooting Common Issues

Zummo Z10
65 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A - 14
are tightened, (Fig. 33) the squeezer will not work and the display will show a fault.
If, for some reason, the squeezing machine, when working, becomes blocked, after a
few seconds the motor will automatically stop and the display will show a fault.
The machine has heat protection systems in the Squeezer Machine and Loader motors
that, in the event of overheating, stop working. In the case of the Squeezer Motor the
DISPLAY will show Fault. In case the Loader Motor the Loader simply will stop.
The glass conveyor motor is protected in such a way that if the conveyor moves and
after 8 seconds the Cup Transporter has not reached the end of its run, the motor stops
and the display shows a fault.
There are two 6.3A 6,3x32 mm fuses on the control panel (Scheme 2) that protect the
low voltage circuit.
A general fuse 10A 6,3x32 mm (Scheme 1 No. 9)
1.8. MAINTENANCE
Squeezer Machine: Grease the roof hinge occasionally. (Fig. 34). (Thick grease –
consistency grade 2 DIN 51818 and distilled water grade 0 corrosion resistance).
Glass conveyor: Grease the guides (Fig. 35 and 36) (water repellent grease).
Attention! Do not use aerosol lubricants, as these would grease the belt, causing it
to slip.
Cooling Unit: Clean the ventilation grilles (Fig. 42).
Loader: Grease the upper and lower bearings. (Thick grease – consistency grade 2
DIN 51818 and distilled water grade 0 corrosion resistance).
1.9. TROUBLESHOOTING
GLASS CONVEYOR: (Fig. 32, 35, 36).
- Check that the drive pulley does not slip on its axis. Should this be the case, tighten the
fastening stud on the pulley.
- Check that the belt does not slip on the drive pulley. Should this be the case, tighten the belt
or apply a non-slip product.
- Check that the photocell led turns on and off when the glass is placed in front of it. Where
necessary, clean the lens (Fig. 39).
- If glasses are on the lower stool, probably is because they have an oval shape. Please
store the glasses so that they are not misshapen.
CUP DISPENSER: (Fig. 19).
- If the “No Glasses” signal appears when there are glasses, It means that the Cup Dispenser
tried three times to dispense a glass but none have fallen. Check that the glasses are not
overly stuck together or misshapen.
LOADER AND ROLLER CONVEYOR: (Scheme 1, No. 14 and 13).
- If the loader does not start, despite there being no oranges on the rollers, check that the
rollers photocell led turns on and off by bringing your hand towards it. Where necessary,
clean the photocell lens (Fig. 40).
- Check that the left end of each roller is in its correct position (Fig. 28). If the rollers have
come out of their housing, then the orange tank may be too full (Fig. 18).
COOLING SYSTEM:
- If there is condensation inside the machine, this implies it is colder outside the machine than
in. This is because the thermostat is adjusted to a temperature that is too high. In winter, the
temperature should be lowered to avoid this. It may also be that the ventilation grilles are
obstructed. Pull the machine away from the wall.