A - 20
2.2. COIN BOX CONNECTION
The machine is prepared to work with EXECUTIVE or MDB Coin Operators:
ATTENTION: BEFORE CONNECTING OR DISCONNECTING THE COIN OPERATOR,
DISCONNECT ZUMMO Z10 BY USING THE GREEN SWITCH! (Scheme 1, No. 18)
- EXECUTIVE COIN OPERATORS: Connect the Coin Operator to the cable supplied with
the machine and connect this to the J2 connector on the control panel (Scheme 2, J2 and
Fig. 8). Program field No. 6 to “0”; see Section 7 of this manual.
- MDB COIN OPERATORS: Connect the Coin Operator to the J1B connector on the control
panel (Scheme 2, J1 and Fig. 9). Program field No. 6 to “1”.
- Adjust the position of the amber coin slot operator part (Fig. 9A) so when you close the
payment door and you activate the amber coin slot operator, this part activates the top
lever of the coin box (Fig. 9B).