5. Verify Firmware Update
a. From your browser, go to http://192.168.1.100/, or use DVRViewer Pro.
b. Verify the new rmware version on the Status page.
6. Recongure TITAN
a. Change all settings to the original elds, as you have recorded, or…
b. Upload the saved conguration le, see UPLOAD CONFIGURATION on page 31.
c. Ensure the DVR name is exactly what it was before.
d. Make sure DVR Server Name on system conguration page is the same name on hard drive.
7. Verify Functionality
a. Turn the key lock to the OPEN position and wait until DVR powers o.
b. Insert hard drive (DHD).
c. Turn the key lock to the LOCK position and wait until the DVR boots up.
d. Reconnect to the DVR at http://192.168.1.100/ using your browser or DVRViewer Pro.
e. Verify new settings by comparing to what you recorded at Step 2e.
f. Download a new conguration le.
g. Launch DVRViewer Pro, click on View/Playback, and select Live Look-in.
h. Verify the live view of cameras.
i. Verify the “Record” LED on the Event Marker is on, indicating that DVR is currently recording
video.
j. Turn the key lock to the OPEN position and wait for TITAN to shut down.
Close your browser and DVRViewer Pro, disconnect crossover cable, close and lock the door.
MCU (MicroController Unit) FIRMWARE UPDATE
NOTE: THIS INFORMATION IS FOR REFERENCE ONLY!
The update process should only be done by a qualied technician under the direction of
technical support. You can seriously impair the functionality of your TITAN.
Firmware updates may contain new features and improvements. If the update process is not done
correctly, your DVR may fail to start or function properly and must be returned to your dealer for repair.
Follow these steps to update your ZEUS MCU rmware. Read all steps before beginning and have
everything you need ready before you start.