Make a hole using the template.
Suppose that all the required cables have been carried
into the hole.
Put the intercom inside and place the set onto the hole
to make sure that the hole is deep enough and the
uneven edge is perfectly covered with the frame.
If the hole is perfect, wall in the flush mounting box.
Remove the front panel from the intercom.
Select the holes for cable supply. Insert the blanks into
the other holes. Apply the cable bushings or a suitable
sealant to prevent penetration of insects or water. You
can also insert the small bushing in the intercom
bottom hole.
Put the frame on the intercom.
Place the intercom into the flush mounting box while
introducing the cables. Leave some of the cables inside
the unit as a reserve and the rest under the intercom
bottom.
Insert the supplied screws in the side mounting holes
making sure that they penetrate into the flush mounting
box nuts. Tighten all the screws properly. Tip: The screw
tightening sequence may affect the intercom position.
We recommend to seal the frame – wall gap with a
silicone or another sealant to avoid wall dampening as a
result of water leakage.
Do not complete mounting until you have finished
electrical installation.
classic bricks.
classic brick wall).
While flush mounting, pull the cables through the device back opening leaving a reserve cable
length behind the device if necessary.
If the cables cannot be cut in the wall deep enough, you can use a smaller hole on the device
bottom.