EasyManua.ls Logo

3Com SuperStack II - X.21 DTE Cable Pinouts

3Com SuperStack II
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
52 CHAPTER 4: CONNECTORS AND CABLES
X.21 DTE Cable
Pinouts
This cable connects the bridge/router to an X.21 DCE.
Figure 24 Flex-WAN and X.21 DTE Connectors
.
Table 16 X.21 DTE Cable Pinouts
Flex-WAN Connector X.21 DTE Connector
Signal Pin Direction Pin Signal Twisted Pair
*
*Unused twisted wires of a twisted pair should be connected to Shield Ground. In this cable this
is one wire of twisted pair 4.
CTS/RTS+ 1 5 Indicate+ 1
CTS/RTS- 2 12 Indicate-
RTS/CTS+ 9 3 Control+ 2
RTS/CTS- 10 10 Control-
TxD/RxD+ 11 2 Transmit+ 3
TxD/RxD- 12 9 Transmit-
Circuit Ground 15 - 8 Control GND 4
RxC/TxCE- 25 13 Timing- 5
RxC/TxCE+ 26 6 Timing+
RxD/TxD- 27 11 Receive- 6
RxD/TxD+ 28 4 Receive+
Shield Ground 46 Cable Shield 1 Shield Ground -
Shorting Group 1 47
48
- - - -
Shorting Group 2 51
52
- - - -
60-pin Flex-WAN male connector
To SuperStack II NETBuilder
To DCE
15-pin male connector
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
31 32 33 34 35 36 37 38 39 40 41 42 43 44 45
60 59 58 57 56 55 54 53 52 51 50 49 48 47 46
HWBook Page 52 Friday, June 19, 1998 3:42 PM