3.4.3. REMOVING AND MOUNTING FILTER SCREEN
In order to clean out the Granulator compartment dismounting the Filter
screen is highly recommended. The Filter screen is placed underneath
the granulator knives and is visible when the Interlock guard is opened.
Different Filter screens can be used to create different granule sizes. The
machine can only be turned on when the Filter screen is placed in the
correct way.
When replacing the Filter screen, always open the shredder
compartment first. The reason for this is that the Filter screen can be
mounted back into the machine a lot easier when the shredder
compartment is opened than when it is closed. Furthermore, it is much
safer to open the shredder compartment when the Filter screen is still in
place.
Step 1. Remove power plug from machine