hydrogen sulfide, ammonia/methylamine,
formaldehyde or hydrogen fluoride and
particulates
1
60928 Organic Vapor/Acid
Gas/P100
Certain organic vapors, chlorine, hydrogen
chloride, and sulfur dioxide or hydrogen sulfide
or hydrogen fluoride and particulates.
2
60929 Mercury Vapor/Chlorine
Gas/P100
Mercury vapor or chlorine gas and particulates
****AAD part numbers are catalog numbers only. NIOSH approved as OH&ESD part numbers
1
OSHA regulations require gas proof goggles be worn with half facepiece respirators when used against
formaldehyde.
2
3M recommended for use against methylbromide or radioiodine up to 5 ppm with daily cartridge
replacement. Note: Not NIOSH approved for use against methylbromide or radioiodine.
Service Life of Chemical Cartridges and Filters
6000 series cartridges should be used before the expiration date on cartridge packaging. The useful service
life of these cartridges will depend upon the activity of the wearer (breathing rate), specific type, volatility
and concentration of contaminants and environmental conditions such as humidity, pressure, and temperature.
Cartridges must be replaced in accordance with an established change schedule, or earlier if smell, taste or
irritation from the contaminant is detected.
Filters must be replaced if they become damaged, soiled or if increased breathing resistance occurs. N-series
filters should not be used in environments containing oils. R-series filters may be limited to 8 hours of
continuous or intermittent use if oil aerosols are present. In environments containing only oil aerosols, P-
series filters should be replaced after 40 hours of use or 30 days, whichever is first.
3M™ Filters, Adapters, Retainers
Note: Only 3M™ Filters approved under NIOSH 42 CFR 84 are to be used with the 3M™ Half Facepiece
6000 Series.
Number ****AAD Description
501 07054 Filter Retainer for Filters 5N11 and 5P71
502 Filter Adapter for Filters 2000 Series and 7093/7093C
2071 Particulate Filter, P95
2076HF Particulate Filter, P95, hydrogen fluoride, with nuisance level acid
gas relief
1
2078 Particulate Filter, P95, 3M recommended ozone protection
2
, with
nuisance level organic vapor/acid gas relief
1
2091 07000 Particulate Filter, P100
2096 Particulate Filter, P100, with nuisance level acid gas relief
1
2097 07184 Particulate Filter, P100, 3M recommended for ozone protection
2
, with
nuisance level organic vapor/acid gas relief
1
7