GENERAL SAFETY INFORMATION
Intended Use
The 3M™ Half Facepiece Respirators 7500 Series are NIOSH approved and designed to help provide respiratory
protection against certain airborne contaminants when used in accordance with all use instructions and limitations
and applicable safety and health regulations.
This product contains no components made from natural rubber latex.
W WARNING
This respirator helps protect against certain airborne contaminants. Misuse may result in
sickness or death.
These User Instructions provide information about facepiece use only. Important information
is provided in the User Instructions with each of the air  ltration/supplied air systems that are
NIOSH certi ed to be used with the 3M™ Half Facepiece Respirator 7500 Series. Failure to follow
User Instructions for the air  ltration/supplied air systems being used may result in sickness
or death.
When in supplied air mode, your employer must provide breathing air that meets at least the
requirements of the speci cation for Grade D breathing air, as described in the Compressed Gas
Association Commodity Speci cation G-7.1-1997 in the United States. In Canada, breathing
air systems must be supplied with air, which meets at least the requirements of CSA Standard
Z180.1. Failure to do so may result in sickness or death.
In Brazil breathing air systems must be supplied with air, which meets ANSI Z86.1-1989/CGA G-7.1, Grade D
breathing air.
USE INSTRUCTIONS & LIMITATIONS
IMPORTANT
Before use the wearer must read and understand these User Instructions. Keep these User Instructions for reference.
Use For
Respiratory protection from certain airborne contaminants according to United States NIOSH approvals, OSHA
limitations, in Canada CSA standard Z94.4 requirements, applicable local government regulations and 3M
instructions. In Brazil follow the Respiratory Protection Program of the Ministry of Labor.
Do Not Use For
Do not use for concentrations of contaminants which are immediately dangerous to life or health, are unknown or
when concentration exceeds 10 times the permissible exposure limit (PEL) in air purifying mode, 50 times PEL in
supplied air mode or according to speci c United States OSHA standards or applicable local government regulations,
whichever is lower.
Use Instructions
1. Failure to follow all instructions and limitations on the use of this respirator and/or failure to wear this respirator
during all times of exposure can reduce respirator effectiveness and may result in sickness or death.
2. Before occupational use of this respirator a written respiratory protection program must be implemented
meeting all the local government requirements. In the United States employers must comply with OSHA 29
CFR 1910.134 which includes medical evaluation, training, and  t testing and applicable OSHA substance
speci c standards. In Canada, follow the recommendations of CSA Z94.4 and/or requirements of the applicable
jurisdiction, as appropriate. In Brazil follow the Respiratory Protection Program of the Ministry of Labor
requirements. When used in supplied air mode, your employer must supply breathing air that meets at least the
requirements of Grade D breathing air in Compressed Gas Association Commodity Speci cations G-7.1-1997.
In Canada, breathing air systems must be supplied with air which meets at least the requirements of CSA
Standard Z180.1.
3. The airborne contaminants which can be dangerous to your health include those that are so small you may not
be able to see or smell them.
4. Leave contaminated area immediately and contact supervisor if you smell or taste contaminants or if dizziness,
irritation, or other distress occurs.
5. Store respirator away from contaminated areas when not in use.
6. Dispose of used product in accordance with applicable regulations.
In Brazil breathing air systems must be supplied with air, which meets ANSI Z86.1-1989/CGA G-7.1, Grade D
breathing air.
Use Limitations
1. This respirator does not supply oxygen when used in air-purifying mode. Do not use in atmospheres containing
less than 19.5% oxygen.
2. Do not use when concentrations of contaminants are immediately dangerous to life and health, are unknown
or when concentrations exceed 10 times the permissible exposure limit (PEL) when used in air-purifying mode,
or according to speci c United States OSHA standards or applicable local government regulations, whichever is
lower. When used as a straight, Type C, continuous  ow supplied air respirator, the Assigned Protection Factor is
50 times the PEL or TLV guidelines for half facepiece respirators.
3. Do not alter, abuse or misuse this respirator.
4. Do not use with beards or other facial hair or other conditions that prevent a good seal between the face and
the faceseal of the respirator.
Time Use Limitations
1. If respirator becomes damaged, leave contaminated area immediately and repair or replace the respirator.
2. Replace  lters in accordance with the  lter Time Use Limitation (See  lter User Instructions).
3. Replace cartridges in accordance with an established change schedule or earlier if smell, taste or irritation from
contaminants is detected.
NIOSH Cautions and Limitations
The following restrictions may apply. See NIOSH approval label.
A - Not for use in atmospheres containing less than 19.5 percent oxygen.
B - Not for use in atmospheres immediately dangerous to life or health.
C - Do not exceed maximum use concentrations established by regulatory standards.
D - Air-line respirators can be used only when the respirators are supplied with respirable air meeting the
requirements of CGA G-7.1 Grade D or higher quality.
E - Use only the pressure ranges and hose lengths speci ed in the User’s Instructions.
G - If air ow is cut off, switch to  lter and/or cartridge or canister and immediately exit to clean air.
H - Follow established cartridge and canister change schedules or observe ESLI to ensure that cartridge and
canisters are replaced before breakthrough occurs.
J - Failure to properly use and maintain this product could result in injury or death.
K - The Occupational Safety and Health Administration regulations require gas-proof goggles to be worn with this
respirator when used against formaldehyde.
L - Follow the manufacturer’s User’s Instructions for changing cartridges, canister and/or  lters.
M - All approved respirators shall be selected,  tted, used, and maintained in accordance with MSHA, OSHA, and
other applicable regulations.
N - Never substitute, modify, add, or omit parts. Use only exact replacement parts in the con guration as speci ed
by the manufacturer.
O - Refer to User’s Instructions, and/or maintenance manuals for information on use and maintenance of these
respirators.
P - NIOSH does not evaluate respirators for use as surgical masks.
S - Special or critical User’s Instructions and/or specic use limitations apply. Refer to User’s Instructions before
donning.
S – Special or Critical User Instructions
3M™ Organic Vapor Service Life Indicator Cartridges (6001i and 60921i) and Mercury Vapor Cartridges (6009S
and 60929S) are equipped with a passive 3M™ End of Service Life Indicator (ESLI). The indicator must be readily
seen when wearing the respirator. If you cannot readily see the ESLI, use a mirror to observe the ESLI, rely on a
co-worker who can see the ESLI, or go to a clean area, remove the respirator and view the ESLI. Do not rely solely on
the organic vapor ESLI unless your employer has determined that it is appropriate for your workplace. See 6001i or
60921i User Instructions for more information, including Special Instructions regarding the ESLI. The mercury vapor
cartridges must be discarded when the ESLI changes to the discard color found on the mercury vapor cartridge
label; or within 30 days of opening packaging; or when ESLI becomes dirty or damaged; or when odors of vapors or
gases become noticeable; or according to chlorine service life, whichever occurs  rst. Mercury vapor has no odor.
To assemble 3M™ Dual Airline Combination Breathing Tubes with 3M™ Cartridges/Filters, the facepiece inhalation
valves must be removed.
If the facepiece is to be used in air-purifying mode (without using the 3M™ Breathing Tubes SA-1600 or SA-2600),
the inhalation valves must be replaced in the facepiece before use.
Cartridge and Filter Selection and Approvals
Before using any of these products, the user must read the specifi c use for, use limitations and warning information
in the User Instructions and product packaging
Do not exceed maximum use concentrations established by local regulatory agencies. Cartridges/ lters are approved
as assemblies for use with 3M™ Half Facepiece 7500 Series. For NIOSH approval, refer to approval label.
LIST OF PRODUCTS
3M™ Half Facepiece 7500 Series Replacement Parts and Accessories
3M™ Half Facepiece 7500 Series
Number ****AAD Description
7501 37081 Small
7502 37082 Medium
7503 37083 Large
**** AAD part numbers are catalog numbers only. NIOSH approved as PSD part numbers
Replacement Parts (Fig. 1A)
Number ****AAD Description
A 7581 Head Harness Assembly
B 7582 Inhalation Valves
C 7586 Cartridge/Filter Holder
D 7583 Exhalation Valve
**** AAD part numbers are catalog numbers only. NIOSH approved as PSD part numbers
Accessories
Number ****AAD Description
504 07065 Respirator Cleaning Wipes
601 Quantitative Fit Test Adapter
6880 37002 Bayonet Cap
**** AAD part numbers are catalog numbers only. NIOSH approved as PSD part numbers
CAUTION
Failure to properly dispose of spent cartridges, lters, or respirators contaminated by hazardous materials can
result in environmental harm. Handling, transportation and disposal of spent cartridges, lters, or respirators must
comply with all applicable federal, state, provincial, and local laws and regulations.
3M™ Cartridges 6000 Series
Number ****AAD Description NIOSH Approval for respiratory protection
against the following contaminants up to ten
times the permissible exposure limit (PEL).
6001 07046 Organic Vapor Certain organic vapors
6001i Organic Vapor with Service Life
Indicator
Certain organic vapors
6002 Acid Gas Chlorine, hydrogen chloride, and sulfur dioxide or
chlorine dioxide or hydrogen sul de
6003 07047 Organic Vapor/Acid Gas Certain organic vapors, chlorine, hydrogen chloride,
and sulfur dioxide or hydrogen sul de or hydrogen
uoride
6004 Ammonia/Methylamine Ammonia and methylamine
6005 Formaldehyde/Organic vapor Formaldehyde and certain organic vapors
1
6006 Multi-Gas/Vapor Certain organic vapors, chlorine, hydrogen chloride,
chlorine dioxide, sulfur dioxide, hydrogen sul de,
ammonia/methylamine, formaldehyde or hydrogen
uoride
1
3
Half Facepiece Respirator 7500 Series
User Instructions for 3M™ Half Facepieces Silicone, Small 7501 (37081), Silicone, Medium 7502 (37082), Silicone,
Large 7503 (37083)*
Important: Keep these User Instructions for reference.
* 37077, 37078, 37079, 37081, 37082, 37083 are catalog numbers only. NIOSH approved as 3M™ Half Facepiece
Silicone, Small 7501, Silicone, Medium 7502, Silicone, Large 7503.
These instructions also apply to the 3M™ Half Facepiece Silicone, Small 37077, Medium 37078 and Large 37079.*
This respirator has dual approval as a United States (US) National Institute for Occupational Safety and Health
(NIOSH) half facepiece respirator and as Brazil Ministry of Labor half mask respirator.
Standard speci c information is provided where applicable. All other information is common to both standards.
Fig. 13
Fig. 12Fig. 11Fig. 10
Fig. 9
Fig. 8
Fig. 7
SA-1500
Fig. 6Fig. 5Fig. 4
Fig. 3
Fig. 2
Fig. 1
Fig. 14 Fig. 15 Fig. 16
Fig. 17 Fig. 18
Fig. 19 Fig. 20
Fig. 21
1
1
Fig. 22
2
2
Fig. 23
Fig. 24 Fig. 25
C
A
B
D
Fig. 1A

Other manuals for 3M 7500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 3M 7500 Series and is the answer not in the manual?

3M 7500 Series Specifications

General IconGeneral
Product TypeHalf Facepiece Respirator
Series7500 Series
MaterialSilicone
Size OptionsSmall, Medium, Large
Connection TypeBayonet
Exhalation ValveYes
NIOSH ApprovalYes
Adjustable StrapsYes
Filter Compatibility3M Filters and Cartridges
WeightVaries by size
UseIndustrial