3M™ Dynatel™ Advanced Modular System 965AMS Measurement Functions
POTS>Level Trace>Operation
3. A dip in the graph indicates
the presence of a load coil.
This graph shows one load
coil.
Note: Level trace cannot
calculate the distance to the
load coil.
4. Use the left and right soft
keys to move the cursor
across the graph. As the
cursor is moved, a readout
of the signal level and
frequency will be displayed
beneath the graph. This
graph shows a circuit with
two load coils.
5. This trace shows one load
coil at 18,000 feet.
Dynatel 965AMS-BT.indd 139 6/21/06 10:49:08 AM