140
Measurement Functions 3M™ Dynatel™ Advanced Modular System 965AMS
Auto Test
Use Auto Test to automatically perform the following
tests: Active POTS, Vacant POTS, Vacant WideBand and Smart
Auto Test.
Auto Test>Active POTS
Use Active POTS to perform an automatic sequence of tests on
Active POTS lines. The tests include: DC Voltage, AC Voltage,
Loop Current, Ground Resistance, Single Tone Loss, Voiceband
Noise (metallic), Voiceband Power Influence and Longitudinal
Balance.
Auto Test>Active POTS>Hook-Up
2%$
'2.
",+
2ING2ING
'ROUND'ROUND
4IP
4IP
Dynatel 965AMS-BT.indd 140 6/21/06 10:49:08 AM