EasyManua.ls Logo

3M Dynatel 2250M User Manual

3M Dynatel 2250M
65 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
3M
Dynatel
Cable/Pipe/Fault Advanced Locator
2250M/2273M Series
(With 3-watt, 5-watt, or 12-watt Transmitter)
Operator’s Manual
2250M
2250M-iD
2273M
2273M-iD
June 2010
78-8130-6150-0-F 3
Advanced Test Equipment Rentals
www.atecorp.com 800-404-ATEC (2832)
®
E
s
t
a
b
l
i
s
h
e
d
1
9
8
1

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the 3M Dynatel 2250M and is the answer not in the manual?

3M Dynatel 2250M Specifications

General IconGeneral
Brand3M
ModelDynatel 2250M
CategoryMeasuring Instruments
LanguageEnglish

Summary

Safety Information

Intended Use

Specifies the intended use of the 3M Cable/Pipe/Fault Advanced M-Series Locator for underground utility lines.

About This Manual

Quick Start

Transmitter Battery Installation

Instructions for installing batteries in the transmitter unit, including cautionary notes.

Receiver Battery Installation

Steps for installing batteries in the receiver unit, with cautionary notes.

Transmitter Keypad and Connector Definitions

Explains the keypad and connector functions of the 3M Dynatel 2250 Transmitter.

2273 Transmitter Keypad and Connector Definitions

Details the keypad and connector functions of the 3M Dynatel 2273 Transmitter.

Maximum Transmitter Output

Information on achieving maximum output levels using external power sources.

Rechargeable Battery

Details the use and specifications of the 3M Dynatel 2200RB rechargeable battery.

2250M Receiver Key Pad and Display Definitions

2273M Receiver Key Pad and Display Definitions

Menu Displays

Main Menu

Explains how to navigate and use the Main Menu for setting up the receiver.

COM Setup

Details COM port settings for communication with GPS devices and PCs.

Setup

Covers receiver configuration for depth units, clock, and language settings.

Self Test

Explains how to perform a self-test on the receiver and view unit information.

Help

Describes how to access on-screen instructions and basic operating information.

Configuring The Receiver

Select Depth Units

Steps to select units of measure (inches, cm, feet/inches) for depth readings.

Setting the Receiver Clock

Instructions for setting the receiver's time, date, and date format.

Selecting a Language

Procedure for selecting the receiver's display language.

Enabling/Disabling Frequencies

How to select frequencies for the receiver to detect.

Selecting External Jack Frequencies (Tone Frequencies)

Procedure for selecting frequencies detectable via the external jack.

Creating User Defined Frequencies

Steps to program custom frequencies for receiver detection.

Filtering Power Frequency Interference

How to filter power frequency interference using user-defined frequencies.

Selecting Locating Audio

How to choose the audio response for Directional Peak mode.

Buried Cables And Pipes: Transmitter Connections

Direct Connect Method

Instructions for using the direct connect method to apply a trace signal.

Dyna-Coupler Method

Steps and warnings for using the Dyna-Coupler method to apply a locating signal.

Induction Method

Explains the induction method for applying a signal when direct connection is not possible.

Non-Sweeping (Passive) Induction Mode Locating

How to trace paths using passive induction without a transmitter.

Sweeping (Active) Induction Mode Locating

Describes active induction sweeps for locating multiple cables without direct access.

Passive Sweeps

How to use passive sweeps with existing signal sources.

One-person Active Induction Mode Sweeps

Instructions for performing active induction sweeps with one operator.

Two-person Active Induction Mode Sweeps

Guide for performing active induction sweeps with two operators.

Receiver Modes

Directional Peak (Dir Pk)

Explains the Directional Peak mode for analyzing magnetic field patterns.

Directional Null (DirNull)

Describes the Directional Null mode for locating cables/pipes.

Special Peak (Spl Pk)

Details the Special Peak mode for deep cables or weak signals.

Induction Peak (Ind Pk)

Explains the Induction Peak mode for minimizing distortion from the magnetic field.

Expanded Mode

Describes the Expanded mode for pinpointing target cables/pipes.

Depth and Current Estimate

Depth Measurement Procedure

How to initiate depth measurement and what readings represent.

Saving Depth Readings

How to save depth readings to memory.

Clearing Depth Data

How to delete all stored depth readings.

Returning to Locate Mode

How to exit the depth measurement function.

Locating Frequencies

Active Frequencies

Using active trace signals supplied by the transmitter.

Power Frequencies

Using passive power frequencies (50/60 Hz and harmonics) for tracing.

Passive Frequencies

Detecting signals like CATV cables using passive frequencies.

Auxiliary Frequencies

Using signals from remote transmitters or frequency generators.

Locating in Directional Peak Mode

Locating Active Duct Probes (Sondes)

Determining ADP Depth

How to measure the depth of an Active Duct Probe.

Locating Buried Sheath Faults and Earth Return Faults

Transmitter Setup

Steps for setting up the transmitter for fault locating.

Pinpointing the Buried Fault

Steps for pinpointing the location of a buried fault using the Earth Contact Frame.

Locating 3M™ Electronic Markers and 3M™ iD Markers

Enabling/Disabling Marker Types

How to enable or disable specific marker types for detection.

Alert Mode

How to set up alert mode for marker detection.

Single Marker Locate

Steps for locating a single marker.

Dual Marker Locate

Steps for locating two markers simultaneously.

ID Marker Depth

How to measure the depth of an iD Marker.

Passive Electronic Marker (Non-iD) Depth

How to measure the depth of a non-iD marker.

Creating/Editing Templates for 3M™ iD Markers

Creating New Templates

Steps to create new templates for iD marker data.

Editing Templates

How to select and modify existing templates.

Writing iD Markers

Modifying Marker Data to be Written

How to alter information before writing it to an iD marker.

Reading iD Markers

Reviewing Marker Read/Write History

Read History

Accessing the historical file of information read from targeted markers.

Write History [SK]

How to view the history of data sent to markers.

GPS Operation

Activation Key

How to enter the activation key to enable GPS compatibility.

Serial Number and Software Version

How to find the unit's model, serial, software, and hardware versions.

Inputting the GPS Activation Key

Steps for entering the GPS activation key.

Communicating with the GPS Device

Configuring COM port settings for GPS device communication.

Capturing the GPS Coordinates (Capture Mode / Mode 1)

How to capture GPS coordinates for marker locations.

Sending iD Marker Data to GPS (Capture-Transmit Mode / Mode 2)

How to send iD marker data directly to GPS devices.

Path Mapping with GPS

Using GPS to map the path of underground target facilities.

Additional Applications

Aerial Faults (Toning)

Using toning for locating aerial faults.

Cable Identification

Steps for identifying cables using Dyna-Couplers.

Help Mode

3M™ Dynatel™ PC Tool Kit and Locator Software Upgrades

Self Test Of Receiver

Product Description And Optional Accessories

Product Description

Details of the 2250M and 2273M locator models.

Standard Configurations

Lists standard packages and part numbers for transmitters and receivers.

Optional 3M™ Dynatel™ Accessories

Lists optional accessories and their part numbers.

Receiver Specifications

Transmitter Specifications

Environmental and Regulatory Specifications

Rechargeable Battery Information

Related product manuals