Electrical Specifications
Functions Range Resolution Accuracy
Noise metallic
600 7Zin C and
psophometric
0 to 50 dBrnc (-90 to
–40 dBm0p)
1 dB ±2 dB
Noise to ground
600 7Zin
40 to 100 dBrnc
(-50 to 10 dBm0p)
1 dB ±2 dB
Longitudinal balance
0 to 85 dB 1 dB ±2 dB
Dial mode
DTMF, pulse Standard Standard
Caller ID (U.S. and
Canada only)
Carrier level
Date, time,
number, name
-4 to –32 dBm
—
1 dBm ±2 dBm
Short range wideband specifications (without SA option)
Wideband loss
100, 135 7 Zin
Wideband tone
output–100,135 7
Zout
-50 to +2 dBm,
20 kHz to 1.2 MHz
0 dBm, 20 k to
2.2 MHz
0.1 dB, 100 Hz
1 kHz
±2 dB, 1% Hz
±+1 dB
SA wideband specifications (with SA option)
Wideband loss
100, 135 7 Zin
-85 to +5 dBm,
20 kHz to 2.2 MHz
0.1 dB, 100 Hz ±1 dB, 1% Hz
Wideband noise metallic
100, 135 7 Zin
E, F, G & G2 filters
E filter 10-90 dBm
F filter 20-90 dBm
G filter 30-90 dBm
1 dB
1 dB
1 dB
±2 dB
±2 dB
±2 dB
Wideband spectral analysis
100, 135 7 Zin
Dynamic range
Wideband tone output
–100,135 7 Zout
10 kHz to 2.2 MHz
–90 dBm to +10 dBm
0 dBm, 20 kHz to
2.2 MHz
0.5% of span
1 dB
1 kHz
1%
±1 dB
±0.1% frequency
±0.5 kHz
Impulse noise counting
E, F, G & G2 filters
Counting interval 1-60 minutes 1 minute ±5%
Threshold Lower limits: 30
dBrnC & E
40 dBrnF
50 dBrnG
100 dBrn upper limit
All 30 dB higher for N
to Ground
1 dB ±1 dB (typical)
Count capacity
9999 1 —