EasyManua.ls Logo

A.O. Smith dve-80 User Manual

A.O. Smith dve-80
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
Service Handbook
PRINTED IN THE U.S.A 0908 315014-000
SERVICING SHOULD ONLY BE PERFORMED BY A QUALIFIED SERVICE AGENT.
COMMERCIAL ELECTRIC WATER HEATERS
MODELS DRE-52/80/120 SERIES 100
& DVE-52/80/120 SERIES 100
INSTALLATION CONSIDERATIONS - PRE SERVICE
CHECKS - WATER HEATER CONSTRUCTION -
OPERATION & SERVICE - TROUBLESHOOTING
500 Tennessee Waltz Parkway
Ashland City, TN 37015
http://waterheatertimer.org/How-to-wire-water-heater-thermostats.html
http://waterheatertimer.org/3-phase-water-heater.html

Table of Contents

Questions and Answers:

A.O. Smith dve-80 Specifications

General IconGeneral
BrandA.O. Smith
ModelDVE-80
TypeElectric Water Heater
Capacity80 Gallons
Power SourceElectric
Voltage240V
Energy Factor0.95
Warranty6 Years
Wattage4500W

Summary

COMMERCIAL ELECTRIC WATER HEATERS

MODELS DRE-52/80/120 SERIES 100 & DVE-52/80/120 SERIES 100

Specifies the models covered by the service handbook.

INTRODUCTION

QUALIFICATIONS - QUALIFIED SERVICE AGENT

Defines the qualifications required for servicing the water heaters.

SERVICE WARNING

Provides a warning for individuals not qualified to perform service.

IMPORTANT SERVICE REMINDER

Highlights critical steps for troubleshooting and avoiding downtime.

TOOLS REQUIRED

ELECTRICAL REQUIREMENTS

Grounding

Stresses the importance of proper grounding according to electrical codes.

Power Supply

Advises verifying power supply phase and voltage against the rating label.

PRE SERVICE CHECKS

SERVICE PRECAUTIONS

Lists crucial safety precautions and procedures before servicing.

WATER HEATER CONSTRUCTION

OPERATION & SERVICE

Checking Single Phase (1Ø) Power

Checking Three Phase (3Ø) Power

FUSES

Thermostat & ECO Test

HEATING ELEMENTS

Heating Element Amperage Test

Heating Element Voltage Test

Heating Element Resistance & Ground Tests

Contactor Coil Voltage - At Contactor

Contactor Coil Voltage - At CCB

TRANSFORMERS

120 VAC Control Circuit Transformer Test

24 VAC Transformer Test

IMMERSION TEMPERATURE PROBE

Temperature Sensor Resistance Test

Temperature Sensor DC Voltage Test

ECO Continuity Test

ECO Voltage Test

ELECTRONIC CONTROLS

Checking Power and Ground To The CCB

ELECTRONIC CONTROL SYSTEM

TEMPERATURES MENU

ECONOMY MODE SETUP MENU

CURRENT FAULT / ALERT MENU

TROUBLESHOOTING

COMMON SERVICE PROBLEMS

Lists common issues and their troubleshooting steps.

ELECTRONIC CONTROL MODELS

Fault Conditions

Describes fault messages and lockout behavior.

CONTROL SYSTEM UNRESPONSIVE

Troubleshooting steps for an unresponsive control system.

FAULT AND ALERT MESSAGES

"No Current Detected" (Alert Condition)

Troubleshooting for "No Current Detected" alert.

Fault & Alert Messages

"Temp Probe Open" (Fault Condition)

Troubleshooting for "Temp Probe Open" fault.

"Energy Cut Out (ECO)" (Fault Condition)

Troubleshooting for "Energy Cut Out (ECO)" fault.

"Temp Probe Short" (Fault Condition)

Troubleshooting for "Temp Probe Short" fault.

Related product manuals