EasyManua.ls Logo

A.O. Smith FPS 75 - Page 37

A.O. Smith FPS 75
103 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK
FPS 40 and 50 SERVICE AND OPERATION cant
BLOWER RUNS CONSTANTLY (No main burner) cant.
Trouble-
shooting cont.
RESULTS
If:
then
the meter does not read 120 VAG,
replace the cable
the meter does read 120 VAG,
go to Step 3
Technical Information
Irving, Texas
36
@1995
A.D. Smith
Water Products Co.

Related product manuals