3. Power measuring
! Ensure that the power of input the power meter is not more than
10dBm
The PowerMeter can only measure directly small power
<10dBmthat is<10mW),When Power is more than 10mW it
needs to be used with the attenuator or coupler to ensure that the
power of entering the PowerMeter is not more than 10mW.
The following is a diagram of the power measurement using a
coupler
The following is a diagram of the power measurement using the
attenuator
For example, to measure the power of a 5W transmitter, 5W=37dBm,
in order to make the input power within the measurement range,
Transmitter output needs to enter a power meter through at least 30dB
coupler
transmitter
Load /antenna
Transmitter
Attenuator