EasyManua.ls Logo

AAI N2201SS - Technical Indicators

AAI N2201SS
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
Technical indicators
Model
N2201SS
Frequency
137.5MHz
2700MHz
Frequency Steps
1kHz
LCD
2.4 Inch TFT 320×240(QVGA)
Battery Capacity
2000mAH(7.4Wh)
Power Consumption
<1.5W
Charging Current
400mA
Charging Interface
Mini USB (only act as charge port)
Micro USB
(only act as charge port)
Automatic Power-Off
Settable (Always Power-On, 5 minutes to 60 minutes optional)
Measurement Parameters
Resistance
Reactance
VSWR
s11
Resolution
4 digits
Frequency Accuracy
<±10ppm
RF Connector
SMA-K
Measurement
Range
Impedance
1000Ω(Absolute value of impedance)
VSWR
1.000
65
s11(dB)
0dB
-50dB
Error
(single-point
measurement)
Impedance
Test conditions
error
Z<200Ω
frequency <1.3GHz
< The absolute value of the impedance×
5
%±0.1Ω
Z>200Ω
frequency >1.3GHz
< The absolute value of the impedance×25%±1Ω
s11
(dB/°)
0dB
-10dB
0.5 dB /5°
-10dB
-20dB
1 dB /10°
-20dB
-40dB
5 dB /20°
VSWR
<2
±0.15
>2
Effective reading×10%±0.1
Directivity(After
calibration)
137.5MHz
2GHz
<35dB
2GHz
2.7GHz
<25dB
Scan Points
280
RF Output Level
frequency range
level
137.5MHz
2000MHz
-11.5dBm
2000MHz
2300MHz
-6dBm
2300MHz
2700MHz
-8dBm
Operating Temperature
5
40
Atmospheric Pressure
860hPa
1060hPa
power meter frequency range
137.5MHz
2700MHz
Maximum detection power
+8dBm
Minimum detection power
-20dBm
Power meter error
Test conditions
error
0dBm-8dBm
±1dBm
-10dBm-0dBm
±1.5dBm
-20dBm--10dBm
±2dBm