CF Series
Condenser and Condensing Units
Installation, Operation,
& Maintenance
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings
exactly could result in serious
injury, death or property damage.
Be sure to read and understand
the installation, operation and
service instructions in this manual.
Improper installation, adjustment,
alteration, service or maintenance
can cause serious injury, death or
property damage.
Keep a copy of this IOM with the
unit.
WARNING
o Do not store gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance
o WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a
phone remote from the building. Follow the
gas supplier’s instructions.
If you cannot reach your gas supplier, call
the fire department.
o Startup and service must be performed by a
Factory Trained Service Technician.
WARNING
UL-60335

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the AAON CF Series and is the answer not in the manual?

AAON CF Series Specifications

General IconGeneral
BrandAAON
ModelCF Series
CategoryHeat Pump
LanguageEnglish

Summary

Installation, Operation, and Maintenance

Safety Warnings

Key safety warnings regarding fire, explosion, and qualified installer requirements.

AAON CF Series Features and Options

General Safety and Handling Precautions

Electrical Shock and Fire Hazards

Warnings about electric shock, fire, explosion, and proper servicing procedures.

Qualified Installer and Lockout Procedures

Emphasis on qualified technicians and proper lockout/tagout procedures.

Unit Handling and Piping Cautions

Unit Handling and Lifting Safety

Safety guidelines for lifting units and handling precautions.

Compressor and Coil Maintenance

Compressor Operation and Cycling

Compressor Cycling Requirements

Specifies minimum ON/OFF times and start rate for compressor protection.

VFD Motor Overload Settings

VFD overload settings are factory-set and must not be bypassed.

Electrical Safety and Installation

Electric Shock Hazard Warning

Critical warning about electric shock and proper power disconnection.

3-Phase Rotation and Voltage Imbalance

Checks for correct 3-phase rotation and potential voltage imbalance issues.

Fuses, Circuit Breakers, and Startup

Pre-Startup Checklist Items

Essential checks to perform before unit startup for safety and operation.

Compressor Controls and Operation

Maintenance Procedures

General Maintenance and Oil Level

Routine checks for pressures, sub-cooling, superheat, and critical oil levels.

Startup Procedures and Data Recording

CF Series Startup Form - Pre-Startup Checklist

Checklist for contractors to verify unit condition before startup.

Maintenance Log and Records