Two Condenser
Head Pressure II Module
Technical Guide
Question and Answer IconNeed help?

Do you have a question about the AAON HP2C2 and is the answer not in the manual?

AAON HP2C2 Specifications

General IconGeneral
BrandAAON
ModelHP2C2
CategoryControl Unit
LanguageEnglish

Summary

Overview

Module Overview

The Two Condenser Head Pressure II Module (ASM01891) monitors four individual head pressure transducers and controls two Condenser Fans or Water Valves.

Installation & Wiring

Mounting and Wiring Considerations

Provides guidance on environmental requirements and important considerations for mounting and wiring the module.

Stand-Alone Wiring

Details the wiring procedures for operating the module in a stand-alone configuration.

E-BUS Controller to Two Condenser Head Pressure II Module Wiring

Explains how to connect the module to E-BUS controllers like VCM-X, WSHP E-BUS, or SA E-BUS.

E-BUS Controller to Two Condenser Head Pressure II Module Wiring (continued)

Details wiring for VCM-X E-BUS controller and related components, including diagrams.

Sequence of Operation

Stand-Alone Input Commands

Describes how to control the module using binary inputs for fan/valve operation in stand-alone mode.

Head Pressure Setpoint

Explains how to set the head pressure setpoint using OPTIONS Dip Switches for stand-alone operation.

ADDRESS Dip Switch Settings for Condenser Type Selection

Details how ADDRESS Dip Switch 1 configures condenser type (Air/Water Cooled) and output signal type.

VCM-X Input Commands and Modes of Operation

Explains module inputs and operational modes (OFF, Cooling, Heating) when connected to VCM-X.

OPTIONS Dip Switch Settings

Provides a table detailing OPTIONS Dip Switch settings for head pressure setpoints for stand-alone operation.

ADDRESS Dip Switch 1 Settings

Details ADDRESS Dip Switch 1 settings for condenser type and default setpoint selection.

ADDRESS Dip Switch 2 Settings

Describes ADDRESS Dip Switch 2 settings for module addressing in communicating mode.

ADDRESS Dip Switch 3 Settings

Details ADDRESS Dip Switch 3 settings for enabling/disabling Circuit B alarms.

ADDRESS Dip Switch 4 Settings

Explains ADDRESS Dip Switch 4 settings for reversing valve control (Heat/Cool).

Troubleshooting

Head Pressure Module Valve; Fan Position Troubleshooting

Troubleshoots valve and fan operation based on Aout signals and PWM signals in cooling/heating modes.

Troubleshooting for Stand-Alone Mode

Provides a flowchart for diagnosing issues when the module operates in stand-alone mode.

Pressure Transducer Troubleshooting and LEDs

Covers troubleshooting using the pressure sensor chart and explains the function of status and alarm LEDs.

LED Diagnostics

Provides detailed explanations for the PWR, COMM, STAT, and ALARM LEDs and their diagnostic functions.