EasyManua.ls Logo

AAON Pioneer Gold User Manual

AAON Pioneer Gold
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Pioneer Gold Controller
Technical Guide
Pioneer Gold Controller Code: SS1128/DT005092-001, Version 2.05 and up
Pioneer Gold Controller Code: SS1108/DT004238-001, Version 1.10
Bootloader: Version 1.04 and up; I/O Board: Version 1.01 and up
Pioneer Gold Touch Screen Temp and Humidity Sensor: Version 2.02 and up
Prism 2 Software: Version 4.9.2 and up
Electric Heat Expansion Module Code: Version 1.0
Used with AAON WSHP WV Series Vertical and WH Series Horizontal

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the AAON Pioneer Gold and is the answer not in the manual?

AAON Pioneer Gold Specifications

General IconGeneral
BrandAAON
ModelPioneer Gold
CategoryController
LanguageEnglish

Summary

OVERVIEW

Safety

Important safety instructions and warnings for handling electrical equipment.

Applications

Describes the systems and units the Pioneer Gold Controller is designed for.

WIRING

Important Wiring Considerations

Key guidelines for correct and safe electrical wiring practices.

Connection Components

Identification of various connection points and components on the controller.

Harness Wiring

Detailed diagrams and descriptions for various system harnesses.

INPUTS & OUTPUTS

Controller Input and Output Descriptions

Detailed explanation of the function for each controller input and output.

SEQUENCE OF OPERATIONS

Space/Room Sensor Controlled Supply Fan

Operational logic for the supply fan based on room sensor input.

Thermostat Controlled Compressor Operation

How the compressor operates under thermostat control.

Alarms

Description of automatic reset alarms and their conditions.

TROUBLESHOOTING

Controller Diagnostics

Using controller LEDs to verify operation and diagnose issues.

Temperature Sensor Testing

Procedure for testing temperature sensors and their voltage/resistance.

Increasing Data Signal Integrity

Methods to improve RS-485 communication reliability.

BACNET® LEGACY PARAMETERS

BACnet® Legacy Parameters

Analog values and descriptions for BACnet® Legacy systems.

BACNET® MS/TP & IP PARAMETERS

BACnet® MS/TP & IP Parameters

Analog values and descriptions for BACnet® MS/TP and IP.

MODBUS POINTS

ModBus Connection

Diagram and notes for establishing a ModBus RTU connection.

ModBus Holding Register Points

List of ModBus holding registers with their addresses and descriptions.

PRISM 2 OVERVIEW

Operator Interface Overview

Introduction to the Prism 2 software interface and its features.

Controller Status Screen

Details of the Pioneer Gold controller status screen and its displayed information.

Controller Setpoint Screens

How to access and modify controller setpoints within Prism 2.

NAVIGATION

Main Screen Icons and Settings Screen Icons

Description of icons used for navigating main and settings screens.

MAIN SCREEN

Main Screen & Step-by-Step Guide

Initial setup steps and overview of the main screen interface.

LOGGING IN

Logging Into the Settings Screens

Procedure for accessing configuration screens via password entry.

SECURITY

Changing Passcodes

Instructions for changing manager and administrator passcodes.

CLOCK

Setting the Time & Daylight Savings Configuration

Procedure for setting the system time and configuring daylight savings.

SCHEDULES

Setting the Operating Schedule

How to configure daily, weekly, and holiday schedules for unit operation.

CONFIGURATION SCREENS

Configuration

Selecting and setting various operational configurations for the controller.

SETPOINTS

Accessing & Entering Setpoints

Procedure for navigating and modifying setpoints via the touch screen.

USB FUNCTIONS

Updating Firmware & Setpoints Using USB

Instructions for updating firmware and transferring setpoints via USB.

NETWORK

Network Information

Setup and configuration of network protocols like ModBus, BACnet, and IP.

ALARMS

Viewing Alarms

How to access and interpret the alarm status screen.

APPENDIX

Remote Touch Screen Sensor Override

Procedure for using and configuring occupancy override on the touch sensor.

Related product manuals