MHGRV-X Controller
Field Technical Guide
Factory Packaged Controls

Questions and Answers:

AAON V12100 MHGRV-X Specifications

General IconGeneral
BrandAAON
ModelV12100 MHGRV-X
CategoryController
LanguageEnglish

Summary

MHGRV-X Controller Overview

MHGRV-X Controller General Information

Provides a general overview of the MHGRV-X controller's capabilities and purpose.

MHGRV-X Controller Features

Details the specific functionalities and benefits offered by the MHGRV-X controller.

Wiring and Installation Guide

Installation and Mounting Procedures

Instructions for physically installing the MHGRV-X controller module.

General Wiring Information

Key considerations and requirements for wiring the MHGRV-X controller.

MHGRV-X to AAON Unit Controller Wiring

Diagram and instructions for connecting the MHGRV-X to an AAON unit controller.

MHGRV-X Stand-Alone Wiring

Diagram and instructions for wiring the MHGRV-X in a stand-alone configuration.

Inputs and Outputs Reference

I/O Map Overview

A map detailing the available inputs and outputs on the MHGRV-X controller.

Analog Inputs Description

Explanation of the analog inputs like Supply Air Temperature and Reset Signal.

Binary Inputs Description

Explanation of binary inputs such as Reheat Enable and Overrides.

Relay Outputs Description

Details on the relay outputs for Fan, Compressor, and Valves.

Operation Modes and Features

Controller Initialization Process

Steps and indicators for the MHGRV-X controller's startup sequence.

Modulating Hot Gas Valves Function

Explanation of how modulating valves control hot gas flow for reheat.

MHGRV-X Operation Modes

Describes the different modes the MHGRV-X controller can operate in.

Stand-Alone Operation Details

How the MHGRV-X functions independently without a main controller.

Auxiliary Mode Stand-Alone

Operation in stand-alone mode using auxiliary inputs for valve control.

Communicating Operation Details

How the MHGRV-X operates as an expansion board for an AAON unit controller.

Auxiliary Mode Communicating

Auxiliary mode operation when communicating with a main unit controller.

Reheat Coil Flush Feature

Procedure to flush the reheat coil for positive oil return to the compressor.

Optional Second Stage Reheat

Information on adding a second stage of reheat capacity.

Reheat Solenoid Valve Control

How the reheat solenoid valve is activated and deactivated.

LCD Display Screens and Navigation

Navigation Keys Overview

Identifies the buttons used to navigate the MHGRV-X controller display.

LCD Display Screen Layout

Visual guide to the controller's LCD display and its navigation keys.

Navigation Key Functions

Detailed functions assigned to each navigation key.

Main Screens Map

Diagram illustrating navigation through the controller's main menu screens.

Main MHG REHEAT Screens

Screens related to the main Hot Gas Reheat (MHG REHEAT) functions.

Status and Alarm Screens

Displays for monitoring controller status and active alarms.

Status Screens Details

Specific information shown on the status screens, including mode and valve position.

Alarm Screens Details

Information on how alarms are displayed and their types.

Setpoint Screens

Screens for viewing and adjusting setpoints for Supply Air Temperature.

Force Valves Screens

Screens for manually controlling valve positions or expansion valves.

Troubleshooting Guide

LED Diagnostics and Indicators

Explanation of the various LEDs for operation, status, and diagnostics.

LED Troubleshooting Tips

Guidance on interpreting LED behavior to diagnose issues.

Alarm Troubleshooting

Steps to diagnose and resolve common alarms like SAT failure or communication loss.

Supply Air Temperature Sensor Checks

Procedures for checking sensor wiring and resistance/voltage readings.

Thermistor Sensor Testing Instructions

Detailed instructions for testing thermistor sensors using resistance and voltage.

Appendix A: Supply Air Temperature Sensor

Supply Air Temperature Sensor Installation

Guide on mounting the SAT sensor in the air duct for accurate readings.

SAT Sensor Wiring Conditions

Wiring requirements based on controller and mode (Stand-Alone vs. Communication).

SAT Options Jumper Settings

Configuration settings for SAT sensor using jumpers.

Appendix B: MHGRV-X Replacement of MHGRV II

Replacing the MHGRV II with MHGRV-X

Step-by-step instructions for replacing an older MHGRV II controller.

Stand-Alone Mode Replacement Steps

Procedure for stand-alone replacement, including wiring and jumper settings.

Communications Mode Replacement Steps

Procedure for replacement when in communications mode.

Appendix C: Reheat Expansion Module

Reheat Expansion Module Features & Dimensions

Overview of the expansion module's capabilities and physical size.

Reheat Expansion Module Installation & Wiring

Guidelines for installing and wiring the reheat expansion module.

Reheat Expansion Module Wiring Diagram

Diagram showing how to wire multiple reheat expansion modules.

Reheat Expansion Module Operation Modes

Describes how the expansion module operates in different modes.

Reheat Expansion Module Additional Features

Additional features specific to the reheat expansion module.

Reheat Expansion Module LED Diagnostics & Troubleshooting

Information on LEDs and troubleshooting for the expansion module.

Reheat Expansion Module Troubleshooting Q&A

Answers to common questions regarding the reheat expansion module.