TA7102i Hardware Installation
© 2014 Aastra Sweden | 153_1531 ANF 90114| A | 2014-01-24 27
RESET/DEFAULT button is not
released while in ResetPending
At run time, if the RESET/DEFAULT
button is released within 5 seconds,
the unit applies default settings,
otherwise the action is cancelled and
the unit goes back to the operation
mode state or it resets.
At start time, the unit stays in this
state until the RESET/DEFAULT
button is released. The unit then
applies the default settings and
restarts.
• steady ON
A firmware pack is downloaded into
the unit and written to persistent
storage.
• cycling from left to
right, individually blinking
1Hz, 33% duty
Triggered after a failure of a firmware
pack download operation. After 4
seconds, the unit restarts.
• blinking at 3Hz,
50% duty. One LED out
of two has a 180 degree
phase. This pattern lasts
for 8 seconds.
Enabled
Triggered after the user has
performed a partial reset procedure.
• blinking
(synchronized)
1Hz, 75% duty
Triggered when the unit is booting on
the recovery bank and no update is
pending.
• blinking, 0.25Hz,
75% duty
configuration in progress
Waiting for DHCP (IPv4 or IPv6)
answer or IPv6 router advertisement
or PPPoE connection.
• Blinking green,
3Hz, 50% duty
Triggered when the unit cannot be
contacted because DHCP failed, PPP
failed, and no static interface is
configured.
• blinking, 3 Hz, 50%
duty.