TA7102i Hardware Installation
© 2014 Aastra Sweden | 153_1531 ANF 90114| A | 2014-01-24 26
These procedures assume that you know the IP address of the TA7102i you want to verify. If
the
TA7102i does not respond, do the following:
• Verify that the LAN and WAN cables are securely connected to the TA7102i and to the
network connectors.
• Be sure that you did not connect crossover network cables.
• Verify the state of the IP network to ensure it is not down (the ETH LED should be ON or
blinking).
4.2 Indicators (LEDs)
The indicators (LEDs) of the TA7102i are described in TA7102i Connectors and Indicators .
LED Patterns – Specific Conditions
Table 5 describes the different states a Aastraunit can have and their associated LED patterns.
Table 5: LED Patterns
RESET/DEFAULT button is pressed
in the ResetPending state. The unit
prepares for a physical shutdown and
restart.
• blinking, 1Hz, 50%
duty
All other LEDs:
• OFF
RESET/DEFAULT button is pressed
at start-time or for at least 7 seconds.
• blinking, 1Hz, 50%
duty