TA7102i Hardware Installation
© 2014 Aastra Sweden | 153_1531 ANF 90114| A | 2014-01-24 29
LED Patterns Default Behaviour
When no specific condition matches those described in Table 5, the LEDs behave individually
according to the following rules:
Table 6: Default LED Behaviour
LED Type
Condition
Behaviour
Power
RestartInProgress
Blinking, 1 Hz, 50% duty
RestartCompleted
Steady ON
ETH
Network traffic
Blinking, variable rate
No network traffic
Steady ON
In Use
Lines Idle and Unlocked
Steady OFF
Lines InUse and
Ul kd
Steady ON
Shutting Down
Steady yellow
Locked
Blinking yellow, 1 Hz, 50% duty
Ready
All lines are enabled
(operational state).
Steady ON
All lines are disabled
(operational state).
Steady OFF
At least one line is
enabled and at least
one line is disabled
Blink 0.25 Hz 75%
4.3 RESET/DEFAULT Button
The RESET/DEFAULT button allows you to:
Cancel an action that was started.
Revert to known factory settings if the TA7102i refuses to work properly for any reason or
the connection to the network is lost.
3. Reconfigure a unit.
At Run-Time
The RESET/DEFAULT button can be used at run-time you can press the button while the
TA7102i
is running without powering the unit off. Table 7 describes the actions you can perform in this
case.