TA7102i Hardware Installation
© 2014 Aastra Sweden | 153_1531 ANF 90114| A | 2014-01-24 30
Table 7: RESET/DEFAULT Button Interaction
RESET/ DEFAULT
Button Pressed for:
Action
Comments
LEDs Pattern
2 to 6 seconds
Restarts the
TA7102i
No changes are made to
the TA7102i settings.
Power LED:
blinking, 1Hz,
50% duty
All other LEDs:
OFF
7 to 11 seconds
Sets the TA7102i
in Partial
Reset Mode
Sets some of the TA7012i
configuration to pre-
determined values.
All LEDs
blinking, 1Hz,
50% duty
12 to 16 seconds
Restarts the
TA7102i in
Factory Reset
Deletes the persistent
configuration, creates a
new configuration file with
the default factory values,
and then restarts the unit.
All LEDs
steady ON
17 seconds and
more
No action is
taken
The RESET/DEFAULT
Button
Pressed event is ignored
N/A
At Start-Time
You can use the RESET/DEFAULT button at start-time you power the unit off, and then
depress the button until the LEDs stop blinking and remain ON. This applies the “Factory Reset”
procedure (see Factory Reset). This feature reverts the TA7102i back to its default factory
settings.