bdiGDB for BDI2000 (PowerPC 7440/7450/86xx) User Manual 21
© Copyright 1997-2015 by ABATRON AG Switzerland V 1.13
3.2.1 Part [INIT]
The part [INIT] defines a list of commands which should be executed every time the target comes out
of reset. The commands are used to get the target ready for loading the program file.
WGPR register value Write value to the selected general purpose register.
register the register number 0 .. 31
value the value to write into the register
Example: WGPR 0 5
WSPR register value Write value to the selected special purpose register.
register the register number
value the value to write into the register
Example: WSPR 27 0x00001002 ; SRR1 : ME,RI
WSR register value Write value to the selected segment register.
register the register number
value the value to write into the register
Example: WSR 0 0x00001002 ; SR0 :
WREG name value Write value to the selected CPU register by name
name the register name (MSR,CR,PC,XER,LR,CTR, ...)
value the value to write into the register
Example: WREG MSR 0x00001002
DELAY value Delay for the selected time. A delay may be necessary to let the clock PLL
lock again after a new clock rate is selected.
value the delay time in milliseconds (1...30000)
Example: DELAY 500 ; delay for 0.5 seconds
WM8 address value Write a byte (8bit) to the selected memory place.
address the memory address
value the value to write to the target memory
Example: WM8 0xFFFFFA21 0x04 ; SYPCR: watchdog disable ...
WM16 address value Write a half word (16bit) to the selected memory place.
address the memory address
value the value to write to the target memory
Example: WM16 0x02200200 0x0002 ; TBSCR
WM32 address value Write a word (32bit) to the selected memory place.
address the memory address
value the value to write to the target memory
Example: WM32 0x02200000 0x01632440 ; SIUMCR