TABLE 1-4. METER CAPACITY VALUES
Meter
Size
Meter
Capacity*
Flow Ranges
0 to Value Tabulated
Capacity Setting
( If not specified by
customer)
Minimum Maximum
inch mm gpm gpm L/min gpm L/min
gpm L/min
1 25 52.83 2.65 10.0 52.8 200.0
16.00 60.0
1
1
2
40 158.5 7.93 30.0 158.0 600.0
50.0 200
m
3
/h m
3
/h
m
3
/h
2 50 264.1 13.3 3.0 264.0 60.0
80.0 20.0
3 80 792.5 39.7 9.0 792.0 180.0
250 60.0
4 100 1056 52.9 12.0 1056.0 240.0
320 80.0
6 150 2641 133 30.0 2641.0 600.0
800 200
8 200 4755 238 54.0 4755.0 1080.0
1500 300
10 250 7925 397 90.0 7925.0 1800.0
2500 550
12 300 10567 528 120.0 10567 2400
3500 800
* Each meter is calibrated to determine its flow capacity at a given velocity, which has been
established as 32.808 ft/s (10 m/s) for the meter capacity (Range DN). The meter capacity expressed
in gpm is recorded on the meter nameplate.
The meter capacity is the base upon which maximum and minimum limits for range settings and
outputs are established.
Flow velocity can be determined as follows:
Meter Capacity:
Flow Velocity (ft/s) = (Operating gpm x 32.808)/Meter Capacity
NOTE
The maximum meter flow range is a function of the signal converter used. The maxi-
mum flow range can not exceed the meter capacity.