Technical data
105
Technical data 
What this chapter contains
This chapter contains the technical specifications of the drive, e.g. the ratings, sizes 
and technical requirements, provisions for fulfilling the requirements for CE and 
other markings and warranty policy.
IEC data
Ratings
The IEC ratings for the ACS800-01 with 50 Hz and 60 Hz supplies are given below. 
The symbols are described below the table.  
ACS800-01 size Nominal 
ratings
No-
overload 
use
Light-overload 
use 
Heavy-duty use  Frame 
size
Air flow Heat 
dissipation
I
cont.max
A
I
max
A
P
cont.max
kW
I
2N
A
P
N
kW
I
2hd
A
P
hd
 kW m
3
/h W
Three-phase supply voltage 208 V, 220 V, 230 V or  240 V
-0001-2 5.1 6.5 1.1 4.7 0.75 3.4 0.55 R2 35 100
-0002-2 6.5 8.2 1.5 6.0 1.1 4.3 0.75 R2 35 100
-0003-2 8.5 10.8 1.5 7.7 1.5 5.7 1.1 R2 35 100
-0004-2 10.9 13.8 2.2 10.2 2.2 7.5 1.5 R2 35 120
-0005-2 13.9 17.6 3 12.7 3 9.3 2.2 R2 35 140
-0006-2 19 24 4 18 4 14 3 R3 69 160
-0009-2 25 32 5.5 24 5,5 19 4 R3 69 200
-0011-2 34 46 7.5 31 7.5 23 5.5 R3 69 250
-0016-2 44 62 11 42 11 32 7.5 R4 103 340
-0020-2 55 72 15 50 11 37 7.5 R4 103 440
-0025-2 72 86 18.5 69 18.5 49 11 R5 250 530
-0030-2 86 112 22 80 22 60 15 R5 250 610
-0040-2 103 138 30 94 22 69 18.5 R5 250 810
-0050-2 141 164 37 132 37 97 30 R6 405 1190
-0060-2 166 202 45 155 45 115 30 R6 405 1190
-0070-2 202 282 55 184 55 141 37 R6 405 1440