Agency Approval
Table 1-4. Agency Approvals
1
NOTES:
1. Hazardous locations approvals for use in flammable atmos-
pheres are for ambient conditions of -25°C to 40°C (-13°F to
104°F), 86 to 106 kPa (12.5 to 15.7 psig) with a maximum oxygen
concentration of 21%.
4. Lock all linkage components in place.
Component Material List
Table 1-5. Component Material List
Component Material
Housing Aluminum
Cover
Inserts
Window
Screws
Range spring 302 stainless steel
Pilot valve (stem & body) 303 stainless steel
Gain hinge spring 302 stainless steel
Cam 302 stainless steel
Cam shaft
Bearings
303 stainless steel
Bronze
Cam follower arm
Bearing
Shaft
Spring arm Aluminum
Zero adjustment nut Aluminum
Indicator
Tubing Silicone
Drive arm Aluminum
Teflon® washers Teflon
Fasteners Steel/stainless steel
Signal connector Nylon
Diaphragms
All except Types AV15 & AV16
Types AV15 and AV16
Diaphragm plastic parts
Rynite® (FR-530) polyethylene
terphthalate
Gauge block (optional) Aluminum
O-rings
All except Types AV15 & AV16
Types AV15 and AV16
Buna-N
Viton®
Manifold (optional)
Adhesive
Handle
Plate
Plug
Valve
Valve handle
Position transmitter
(AV
_
_ _ _ 1/2 _ _)
Gears
Gear hub
Delrin® (coolymer acetal)
Brass
Additional Type AV2 comps
Tubing
I/P converter
AVI and AV2 POSITIONERS | SOI/AV12 RE V. A
5
Nome nc la tu re Approval/Certification
AV1 and AV23
Factory Mutual Research (
C
FM
US
):
FM Approvals - FM16US0321
FM Approvals Canada - FM16CA0160
Approved as nonincendive for:
Class I, Div 2, Groups A, B, C, D / T5 Ta = 40°C
Class II, Div 2, Groups E, F and G / T5 Ta = 40°C
Class III, Div 2 / T5 Ta = 40°C
AV27_ _ 0_ _
Factory Mutual Research (FM):
Approved as explosionproof for:
X.P: Class I ; Division 1, Groups B, C, D
D.I.P: Classes II, III ; Division 2, Groups E, F, G
Canadian Standards Association (CSA)
Certified as explosionproof for:
Classes I ; Division 1, Groups B, C, D
Refer: ABB - TEIP11 I/P Signal Converter
Install per : OI/TEIP11/TEIP11-PS
All
Complies with the EC directive for CE conformity.
2014/30/EU - Electromagnetic Compatibility EMC
2011/65/EU & 2015/863/EU - RoHS Directive