CoriolisMaster FCB400, FCH400 CORIOLIS MASS FLOWMETER | OI/FCB400/FCH400-EN REV. E 9
Basic model
FCa4c d m f g h i j k l m
Design / transmitter housing / transmitter housing material / cable gland
Integral mount / dual-compartment housing / aluminum / 3 × M20 × 1.5
D1
Integral mount / dual-compartment housing / aluminum / 3 × NPT ½ in D2
Integral mount / dual-compartment housing / aluminum / 3 × M20 × 1.5 (Ex d / XP)
D5
Integral mount / dual-compartment housing / aluminum / 3 × NPT ½ in (Ex d / XP) D6
Integral mount / dual-compartment housing / stainless steel / 3 × M20 × 1.5
D3
Integral mount / dual-compartment housing / stainless steel / 3 × NPT ½ in D4
Integral mount / dual-compartment housing / stainless steel / 3 × M20 × 1.5 (Ex d /
XP)
D7
Integral mount / dual-compartment housing / stainless steel / 3 × NPT ½ in (Ex d /
XP)
D8
Integral mount / single-compartment housing / aluminum / 3 × M20 × 1.5 S1
Integral mount / single-compartment housing / aluminum / 3 × NPT ½ in
S2
Remote mount / dual-compartment housing / aluminum / 3 × M20 × 1.5
R1
Remote mount / dual-compartment housing / aluminum / 3 × NPT ½ in
R2
Remote mount / dual-compartment housing / aluminum / 3 × M20 × 1.5 (Ex d / XP)
R5
Remote mount / dual-compartment housing / aluminum / 3 × NPT ½ in (Ex d / XP)
R6
Remote mount / dual-compartment housing / stainless steel / 3 × M20 × 1.5
R3
Remote mount / dual-compartment housing / stainless steel / 3 × NPT ½ in
R4
Remote mount / dual-compartment housing / stainless steel / 3 × M20 × 1.5 (Ex d /
XP)
R7
Remote mount / dual-compartment housing / stainless steel / 3 × NPT ½ in (Ex d /
XP)
R8
Remote mount / single-compartment housing, wall mounting / aluminum /
4 × M20 × 1.5
W1
Remote mount / single-compartment housing, wall mounting / aluminum / 4 × NPT
½ in
W2
Remote mount / not specified
Y0
Outputs
Current output 1 (active or passive), digital output 1 & 2 (passive),
HART®, PROFIBUS DP®
D1
Current output 1 (active), digital output 1 & 2 (passive), HART®, Modbus® M1*
Current output 1 (active / passive), digital output 1 & 2 (passive), HART
G0
Current output 1 (active / passive), digital output 1 & 2 (passive),
24 V DC transmitter loop power supply, HART®
G1
Current output 1 (active / passive), digital output 1 & 2 (passive),
current output 2 (passive), HART®
G2
Current output 1 (active / passive), digital output 1 & 2 (passive),
current output 2 (passive), current output 3 (passive), HART®
G3
Current output 1 (active / passive), digital output 1 & 2 (passive),
current output 2 (passive), 24 V DC transmitter loop power supply, HART®
G4
Without Y0
Power supply
100 to 230 V AC
A
11 to 30 V DC
C
Without
Y
* The M1 design is identical in construction to the M5 design, as it can also be called in other locations

Table of Contents