3
Table 1 - Mounting Dimensions
Coupling Size
Clamp Ring Screw Wrench Torque (lb-in)
Distance Between Flanges
B (in)
Total Difference
See Figure 8 (below)
C (in)
Flange Style
Two-Piece
Flange Style
Three-Piece
PX40 130 130 49/64 1/64
PX50 130 130 31/32 1/64
PX60 290 290 1-9/32 1/64
PX70 290 290 1-1/2 1/64
PX80 290 290 1-1/ 2 1/64
PX90 480 480 1-17/32 1/32
PX100 480 480 1-23/32 1/32
PX110 480 480 1-9/16 1/32
PX120 1080 1080 1-3/4 1/32
PX140 1080 1080 2-1/16 1/32
PX160 2160 1150 2-11/16 1/16
PX200 2160 2400 3-5/16 1/16
PX240 3600 4020 3-29/32 1/16
PX280 4320 6600 4-7/32 1/16
PX320 4320 6600 4-1/2 1/16
Coupling Size Clamp Ring Screw Torque (Nm)
Thread Size Flange Style
Two-Piece
Flange Style
Three-Piece
Distance Between
Flanges "B" (mm)
Total Difference
"C" (mm)
PXM 40 M6 15 15 19.4 0.4
PXM 50 M6 15 15 24.6 0.4
PXM 60 M8 36 36 32.5 0.4
PXM 70 M8 36 36 38.1 0.4
PXM 80 M8 36 36 3 8.1 0.4
PXM 90 M10 72 72 38.9 0.8
PXM 100 M10 72 72 43.7 0.8
PX M 110 M10 72 72 39.7 0.8
PXM 120 M12 125 125 44.5 0.8
PXM 140 M12 125 125 52.4 0.8
PXM 160 M16 311 130 68.3 1.6
PXM 200 M16 311 271 8 4.1 1.6
Table 2 - Set Screw Torque
Inch Set Screw Size #0 #1 #2 #3 #4 #5 #6 #8 #10 1/4 5/16 3/8 7/16 1/2 9/16 5/8 3/4 7/8
Torque (lb-in) 1 1.8 1.8 5 5 10 10 20 36 87 165 290 430 620 1325 2400 5200 7200
Torque (Nm) 0.1 0.2 0.2 0.6 0.6 1.1 1.1 2.3 4.1 9.8 18.6 32.8 48.6 7 0.1 149.7 271.2 5 87.5 813.5
Metric Set Screw Size M4 M5 M6 M8 M10 M12 M16 M20
Torqe (in-lbs) 19 35 64 150 290 480 1190 2100
Installation Torque (Nm) 2.2 4 7. 2 17 33 54 134 237
ATEX Approved PARA-FLEX Couplings
These instructions do not cover all details or variations in
equipment nor provide every possible contingency or hazard
to be met in connection with installation, operation, and
maintenance. Should further information be desired, or should
particular problems arise which are not covered in this manual,
the matter should be referred to your local ABB representative.
DODGE Elastomeric couplings are manufactured under the
guidelines of the ATEX directive 2014/34/EU.
DODGE Elastomeric couplings are suitable for ATEX category
2 and M2, Group II and I for gas and dust environments
and are also suitable for ATEX category 3 for all gas or dust
environments with ignition temperatures higher than T5 = 100°
C.
A sticker indicating ATEX certication will be attached to the
product or on the box containing the product and will be similar
to the following:
OR
Figure 9 - ATEX Certification
WARNING: These couplings are designed to operate with surface
temperatures below 100°C when properly installed and selected.
Excessive temperatures greater than 80°C is a result of an
abnormal operating condition caused by:
1. Improper installation - refer to installation manual for
proper procedures
2. Excessive misalignment - re-align coupling / shafts
3. Failure of the coupling element - replace elastomeric
4. Excessive speed - re-evaluate application and selection
5. Excessive vibration - determine source, re-evaluate
application
If applied in a Division 1 or Zone 1 environment, the excessive
temperature may cause ignition of hazardous materials.