Emax X1-Tmax T7-Tmax T8
Operating istructions for T7-T8-X1 low
voltage air circuit breakers protection
releases
Operating instructions
1SDH000587R0002
B1751

Table of Contents

Other manuals for ABB Emax X1

Questions and Answers

  • M
    Michael MarshAug 9, 2025
    Why are the ABB Other trip times higher than expected?
    • M
      Mike CainAug 9, 2025
      If the trip times for your ABB Other are higher than expected, the threshold or curve might be set too high. Another possibility is that the curve type is set to "t=k/I2". Finally, the neutral selection could be incorrect. To resolve this, correct the threshold and curve, select the curve type "t=k", and ensure the neutral adjustment is correct.
  • L
    Lisa LopezAug 14, 2025
    Why are the ABB Other trip times lower than expected?
    • S
      snyderalexisAug 14, 2025
      If the trip times for your ABB Other are lower than expected, it could be due to a threshold or curve that is set too low, or an incorrect neutral selection. To fix this, correct the threshold and curve settings, and ensure the neutral adjustment is correct.
  • M
    melissa77Aug 20, 2025
    How to troubleshoot ABB Other when the trip test cannot be run?
    • M
      Mark Crane PhDAug 20, 2025
      If the trip test for your ABB Other cannot be run, it could be due to several reasons. First, check if the busbar current is greater than 0, as it should be in normal operation (FN). Second, verify the TC connection. Lastly, ensure the PR030/B unit is properly connected.
  • M
    Michael ChambersAug 27, 2025
    What to do if the expected trip does not happen with ABB Emax X1 Other?
    • A
      Anthony SullivanAug 27, 2025
      If the expected trip does not occur with your ABB Other, the protection function might be turned off. To resolve this, enable the protection function (FN).
  • J
    James WilkinsSep 1, 2025
    What causes rapid trip with I3=Off in ABB Emax X1?
    • J
      Jennifer OrtegaSep 1, 2025
      A rapid trip with I3=Off in your ABB Other is likely caused by an instantaneous trip (Iinst tripped). This suggests a short-circuit with high current (FN).

Summary

General Notes on Protection Releases

Safety Notes

Provides crucial warnings and safety precautions for handling and servicing the equipment.

PR331;P Protection Release

Main Specifications of PR331;P

Details the key specifications including protections, functions, accessories, and compatibility.

User Interface of PR331;P

Describes the front panel interface, including dip switches, LEDs, and the 'iTest' button.

PR331;P Protection Functions

Test Connector and Protection L

Explains the test connector and details the overload protection (L) function.

Protections S, I, MCR, G, Neutral

Describes short-circuit (S, I, MCR), earth fault (G), and neutral protections.

linst Protection and Summary Table

Details linst protection and provides a summary table of all protections.

PR331;P Main Functions

Putting into Service and Recommendations

Provides guidance on installation and initial setup of the protection release.

Connections and Default Parameters

Default Parameters

Lists the default settings for protections, frequency, and other parameters upon supply.

Troubleshooting PR331;P

PR332;P and PR333;P Protection Releases

Specifications: Protections, Functions, I;O

Details the protections, functions, inputs/outputs of the PR332/P and PR333/P releases.

User Interface for PR332;P and PR333;P

Alarms, Messages, and Icons

Details the alarm messages, icons, and their corresponding descriptions for fault indication.

Protection Functions Overview

Protections L, S, S2

Details protections L (overload) and S, S2 (short-circuit), including curves and thermal memory.

Protections D, G, Gext

Describes directional D, earth fault G, and external earth fault Gext protections.

Protections I, MCR, Rc, U

Details protections I, MCR, Rc (residual current), and U (current unbalance).

Protections UV, OV, RV, RP, UF, OF, T

Describes protections for voltage, frequency, power, and temperature.

Summary Table of PR332;PR333;P Protections

Provides a detailed summary table of all protection functions for PR332 and PR333/P.

Measuring Functions

Runtime Measurements: Current, Voltage, Power

Details available measurements for phase/neutral currents, voltages, and power.

Settings Menu Configuration

Test Menu Options

Putting into Service and Recommendations

Troubleshooting

Common Faults and Solutions

Table listing common situations, their possible causes, and suggested solutions.

Handling Faulty Operation and Trips

Provides instructions for reporting and diagnosing faults and unexpected trips.

ABB Emax X1 Specifications

General IconGeneral
Rated VoltageUp to 690V AC
Poles3P, 4P
Rated operational voltageUp to 690V AC
Communication ProtocolsModbus, Profibus
DimensionsVaries depending on configuration. Consult ABB documentation for specific dimensions.
WeightVariable depending on model
StandardsIEC 60947-2
TypeAir Circuit Breaker
MountingFixed
Protection FunctionsOvercurrent, Short-circuit, Ground fault